@ARTICLE{Barlik_Roman_Estimation_2016, author={Barlik, Roman and Nowak, Mieczysław and Grzejszczak, Piotr and Zdanowski, Mariusz}, volume={vol. 65}, number={No 3 September}, journal={Archives of Electrical Engineering}, pages={613-627}, howpublished={online}, year={2016}, publisher={Polish Academy of Sciences}, abstract={This paper presents the implementation of a thermal camera for the quantitative estimation of power losses in a high frequency planar transformer (100 kHz/ 5600 VA). The methodology is based on the observation of the transient temperature rise and determination of the power losses by means of curves representing the derivative of temperature as a function of power losses dissipated in the transformer. First, the thermal calibration characteristics had to be obtained from a simple experiment, where power losses are generated by DC current in the ferrite core and windings. Next, experimental investigations focused on the determination of the transformer power losses for a short circuit and no load, with a resistive load and with the rectifier as a load were carried out. Finally, to verify the obtained results, analytical calculations based on Dowell’s and modified Steinmetz’s equations were additionally made, which showed a good convergence. The proposed method is easy to implement and can be used as an alternative to the calorimetric method which is time-consuming and requires a complicated measurement setup.}, type={Artykuły / Articles}, title={Estimation of power losses in a high-frequency planar transformer using a thermal camera}, URL={http://journals.pan.pl/Content/102163/PDF/DOI%2010.1515aee-2016-0044.pdf}, doi={10.1515/aee-2016-0044}, keywords={power losses estimation, thermal camera, thermal calibration, planar transformer, Dowell’s and Steinmetz’s equations}, }