@ARTICLE{Shi_Hong_Optimization_2024, author={Shi, Hong and Wang, Rui and Chen, Mingmin and Wang, Jiao and Yuan, Jie and Zhang, Qianwei and Yang, Kaijie}, volume={72}, number={2}, journal={Bulletin of the Polish Academy of Sciences Technical Sciences}, pages={e148834}, howpublished={online}, year={2024}, abstract={In response to the problems of high-temperature gas intrusion and ablation in the expansion slit between ceramic tiles under complex flow conditions in the floating-wall combustion chamber, as well as the issue of hooks exceeding their service temperature, numerical simulations and analysis were conducted for this paper. The study revealed the mechanisms of gas intrusion and sealing and proposed two evaluation metrics for evaluating the cooling effect: the maximum temperature of the hook and the proportion of high-temperature area on the sidewall of the tile. Furthermore, the CRITIC weighting method was used to analyze the weight of these metrics. Based on this, the spacing, radius, and length effects on sealing and cooling effectiveness were studied, and multi-parameter calculations and optimization were performed. The results showed that the degree of gas intrusion in the transverse slit was significantly higher than that in the longitudinal slit. In addition, the sealing method of the jet impingement could effectively cool the downstream of both the transverse and longitudinal slit. The spacing of the jet impingement holes had the greatest impact on the cooling effect, followed by the radius and length. Finally, when the spacing of the holes is 10 mm, the length is 18.125 mm, and the radius is 1.6 mm, the cooling effect is optimal, with the proportion of high-temperature area on the side wall of the tile being 20.86% and the highest temperature of the hook reaching 836.02 K.}, type={Article}, title={Optimization sealing and cooling to control gas intrusion in a floating-wall combustion chamber}, URL={http://journals.pan.pl/Content/129620/PDF/BPASTS-03821-EA.pdf}, doi={10.24425/bpasts.2024.148836}, keywords={gas turbine, floating-wall combustion chamber, gas intrusion, jet impingement cooling, CRITIC weighting}, }