Details Details PDF BIBTEX RIS Title The Determination Of Diffusive Tortuosity In Concrete Specimens Using X-Ray Microtomography Journal title Archives of Metallurgy and Materials Yearbook 2015 Numer No 2 June Authors Ranachowski, Z. ; Ranachowski, P. ; Dąbrowski, M. ; Jóźwiak-Niedźwiedzka, D. ; S. Kudela ; Dvorak, T. Divisions of PAS Nauki Techniczne Publisher Institute of Metallurgy and Materials Science of Polish Academy of Sciences ; Commitee on Metallurgy of Polish Academy of Sciences Date 2015[2015.01.01 AD - 2015.12.31 AD] Identifier DOI: 10.1515/amm-2015-0140 ; ISSN 1733-3490 References Lanzon (2012), de Kock ray microtomography ( μ - to evaluate microstructure of mortars containing low density additions Cement Composites, Concrete, 993. ; Gallucci (2007), Experimental investigation of the microstructure of cement pastes using synchrotron ray microtomography ( uCT Cement Research, Concrete, 360. ; Garboczi (2002), Three - dimensional mathematical analysis of particle shape using ray tomography and spherical harmonics : Application to aggregates used in concrete Cement Research, Concrete, 1621. ; Provis (2012), ray microtomography shows pore structure and tortuosity in alkali - activated binders Cement Research, Concrete, 855. ; Stock (2001), ray microtomography ( micro - of the progression of sulfate attack of cement paste Cement Research, Concrete, 1673.