Details

Title

Detection of Gaseous Compounds with Different Techniques

Journal title

Metrology and Measurement Systems

Yearbook

2016

Volume

vol. 23

Issue

No 2

Authors

Keywords

gas sensors ; laser absorption spectroscopy ; CEAS ; MUPASS ; breath analyses ; medical screening

Divisions of PAS

Nauki Techniczne

Coverage

205-224

Publisher

Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation

Date

2016.06.30

Type

Artykuły / Articles

Identifier

DOI: 10.1515/mms-2016-0026 ; ISSN 2080-9050, e-ISSN 2300-1941

Source

Metrology and Measurement Systems; 2016; vol. 23; No 2; 205-224

References

Wojtas (2012), Ultrasensitive laser spectroscopy for breath analysis Opto, Electron Rev, 71, 77. ; Stelmaszczyk (2000), New Method of Elaboration of the Lidar Signal, Appl Phys, 54, 295, doi.org/10.1007/s003400050048 ; Berden (2000), Cavity ring - down spectroscopy Experimental schemes and applications, Int Rev Phys Chem, 64, 565, doi.org/10.1080/014423500750040627 ; Nakhleh (2014), Monolayer - capped gold nanoparticles for disease detection from breath, Nanomedicine, 21, 1991, doi.org/10.2217/nnm.14.121 ; Hodgkinson (2013), Optical gas sensing : a review Metrol, Meas Syst, 2, 1. ; Hodgkinson (2013), Non - dispersive infra - red NDIR measurement of carbon dioxide at μm in a compact and optically efficient sensor Sens Actuators, Chem, 36, 186. ; Szabra (2014), Power supply systems for quantum cascade lasers structures technologies applications, Electronics, 42, 50. ; Wang (2009), Breath Analysis Using Laser Spectroscopic Techniques : Breath Biomarkers , Spectral Fingerprints , and Detection Limits, Sensors, 74, 8230, doi.org/10.3390/s91008230 ; Menzel (2001), Spectroscopic detection of biological NO with a quantum cascade laser, Appl Phys, 44, 859, doi.org/10.1007/s003400100562 ; Engel (1998), Cavity enhanced absorption and cavity enhanced magnetic rotation spectroscopy, Rev Sci Instrum, 67, 3763, doi.org/10.1063/1.1149176 ; Heszler (2007), On the selectivity of nanostructured semiconductor gas sensors, Phys Status Solidi, 23, 244. ; Smulko (2015), Gas selectivity enhancement by sampling - and - hold method in resistive gas sensors Sens Actuators, Chem, 20, 219. ; Le Marchand (1992), Use of breath hydrogen and methane as markers of colonic fermentation in epidemiologic studies : circadian patterns of excretion, Environ Health Perspect, 83, 199, doi.org/10.1289/ehp.9298199 ; Kish (2000), Extracting information from noise spectra of chemical sensors : single sensor electronic noses and tongues Sens Actuators, Chem, 27, 55. ; Hierlemann (2003), CMOS - based chemical microsensor, Analyst, 128. ; Li (2012), A high heating efficiency two beam microplate for catalytic gas sensors of the IEEE International Conference on Micro Electronic and Mechanical Systems MEMS Kyoto Japan, Proc, 6, 65. ; Kotarski (2009), Noise measurement set - ups for fluctuations - enhanced gas sensing Metrol, Meas Syst, 31, 457. ; Halek (2009), Methods of selectivity improvements of semiconductor gas sensors of the International Students and Young Scientists Workshop on Photonics and Microsystem Wernigerode, Proc, 24, 31. ; Szabra (2013), Quantum cascade laser driving in optical spectroscopy, Electrotechnical Review, 43, 173. ; Neill (1988), A computerized classification technique for screening for the presence of breath biomarkers in lung cancer, Clin Chem, 63, 1613. ; Vreman (1995), Carbon monoxide and carboxyhemoglobin, Adv Pediatr, 77, 330. ; Ederth (2006), Comparison of classical and fluctuation - enhanced gas sensing with PdxWO nanoparticle films Sens Actuators, Chem, 22, 310. ; Yunusa (2014), Gas sensors : a review Transducers, Sensors, 10, 61. ; Comini (2000), Light enhanced gas sensing properties of indium oxide and tin dioxide sensors Sens Actuators, Chem, 26, 260. ; Park (2009), A micro - thermoelectric gas sensor for detection of hydrogen and atomic oxygen, Analyst, 134. ; Cygan (2011), Pound Drever Hall - locked frequency - stabilized cavity ring - down spectrometer, Rev Sci Instrum, 65, 063107, doi.org/10.1063/1.3595680 ; Markowicz (2012), Remote sensing measurements of the volcanic ash plume over Poland in April Environment, Atmospheric, 53, 66, doi.org/10.1016/j.atmosenv.2011.07.015 ; Stacewicz (2003), Studies of physical processes in the Earth s atmosphere Radiat, Phys Chem, 57, 57. ; Stacewicz (2012), Cavity Ring Down Spectroscopy : detection of trace amounts of matter Opto, Electron Rev, 70, 34. ; Ohira (2008), Micro gas analyzers for environmental and medical applications, Anal Chim Acta, 12, 619. ; Matatagui (2012), Love - wave sensor array to detect , discriminate and classify chemical warfare agent simulants Sens Actuators, Chem, 33, 175. ; Keefe (1988), Cavity ring - down optical spectrometer for absorption measurements using pulsed laser source, Rev Sci Instrum, 62, 2544. ; Stevenson (1997), Carbon monoxide and bilirubin production in neonates, Pediatr Rev, 78, 252. ; Wojtas (2014), Cavity enhanced absorption spectroscopy and photoacoustic spectroscopy for human breath analysis, Int J Thermophys, 59, doi.org/10.1007/s10765-014-1586-4 ; Chudzyński (1996), Lidar monitoring of the atmosphere, Proc SPIE, 51, 3188. ; Kosterev (2002), Quartz - enhanced photoacoustic spectroscopy, Opt Lett, 60, 1902, doi.org/10.1364/OL.27.001902 ; Bielecki (2012), Sensors and Systems for the Detection of Explosive Devices An Overview Metrol, Meas Syst, 1, 3. ; Jasinski (2003), Nanocrystalline undoped ceria oxygen sensor Sens Actuators, Chem, 16, 73. ; Thorpe (2006), Broadband cavity ringdown spectroscopy for sensitive and rapid molecular detection, Science, 82, 311. ; Xiong (2014), Amperometric Gas detection, Review Int J Electrochem Sci, 15, 7152. ; Zayasu (1997), Increased carbon monoxide in exhaled air of asthmatic patients, Am Respir Crit Care Med, 81, 156. ; Osowski (2014), Differential electronic nose in on - line dynamic measurements Metrol, Meas Syst, 32, 649. ; Graaf (2012), de Surface micromachined thermal conductivity detectors for gas sensing of the IEEE International Instrumentation and Measurement Technology Conference, Proc, 13, 1861. ; Vidybida (2003), Adsorption - desorption noise can be used for improving selectivity Sens Actuators, Phys, 29, 233. ; Wojtas (2011), Applying CEAS method to UV VIS and IR spectroscopy sensors Pol, Bull Acad Sci Tech Sci, 69, 1. ; Stacewicz (2016), Detection of disease markers in human breath with laser absorption spectroscopy Opto ( to be published ), Electron Rev, 84. ; Gwiżdż (2015), Hydrogen detection with a gas sensor array - processing and recognition of dynamic responses using neural networks Metrol, Meas Syst, 17, 3. ; Bielecki (2015), Application of quantum cascade lasers to trace gas detection Pol, Bull Acad Sci Tech Sci, 63, 515. ; Namjou (1998), Sensitive absorption spectroscopy with a room - temperature distributedfeedback quantum - cascade laser, Optics Letters, 38, 219, doi.org/10.1364/OL.23.000219 ; Cygan (2013), Spectral line - shapes investigation with Pound - Drever - Hall - locked frequency - stabilized cavity ring - down spectroscopy, Eur Phys J Spec Top, 66, 222. ; Lentka (2015), Determination of gas mixture components using fluctuation enhanced sensing and the LS - SVM regression algorithm Metrol, Meas Syst, 25, 341. ; Yoshii (2003), Long - Path Measurement of Atmospheric NO with an Obstruction Flashlight and a Charge Coupled Device Spectrometer, Applied Optics, 45, 4362, doi.org/10.1364/AO.42.004362 ; Applegate (1991), Induction of heme oxygenase : a general response to oxidant stress in cultured mammalian cells, Cancer Res, 79, 974. ; Dziedzic (1999), Noise and nonlinearity of gas sensors - preliminary results nd Int Spring Seminar on Electronics Technology Dresden - Freital, Proc, 28, 22. ; Yamaya (1998), Increased carbon monoxide in exhaled air of subjects with upper respiratory tract infections, Am Respir Crit Care Med, 80, 158. ; Robinson (2011), Infrared differential absorption Lidar DIAL measurements of hydrocarbon emissions, J Environ Monit, 55, 2213, doi.org/10.1039/c0em00312c ; Tittel (2012), Sensitive detection of nitric oxide using a μm external cavity quantum cascade laser based QEPAS sensor SPIE, Proc, 61. ; Birrell (2006), Utility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model, Eur Respir J, 72, 1236, doi.org/10.1183/09031936.00048506
×