Details

Title

The Influence of Mechanical, and Material Factors on the Biological Adaptation Processes of the Femoral Bone Implants

Journal title

Archives of Metallurgy and Materials

Yearbook

2016

Issue

No 1 March

Authors

Divisions of PAS

Nauki Techniczne

Publisher

Institute of Metallurgy and Materials Science of Polish Academy of Sciences ; Committee of Materials Engineering and Metallurgy of Polish Academy of Sciences

Date

2016

Identifier

DOI: 10.1515/amm-2016-0033 ; e-ISSN 2300-1909

Source

Archives of Metallurgy and Materials; 2016; No 1 March

References

Tudor (2013), The effect of clearance and wear on the contact pressure of metal on polyethylene hip prostheses, Tribology International, 63. ; Taddei (2006), Finite - element modeling of bones from CT data : sensitivity to geometry and material uncertainties, IEEE Trans Biomed Eng, 53, 2194, doi.org/10.1109/TBME.2006.879473 ; Shankar (2014), Dynamic contact analysis of total hip prosthesis during stumbling cycle of Mechanics in Medicine and Biology No, Journal Vol, 14. ; Huiskes (1987), Adaptive bone - remodeling theory applied to prosthetic - design analysis, J Biomech, 11, 1135, doi.org/10.1016/0021-9290(87)90030-3 ; Sithi (2015), Shameem Human gait recognition using silhouettes of Applied Engineering Research, International Journal, 10, 5443. ; Eskitascioglu (2004), The influence of occlusal loading location on stresses transferred to implant - supported prostheses and supporting bone : A three - dimensional finite element study The, Journal Of Prosthetic Dentistry, 91, 144, doi.org/10.1016/j.prosdent.2003.10.018 ; Miller (2002), Trabecular bone adaptation with an orthotropic material model, J Biomech, 35, 247, doi.org/10.1016/S0021-9290(01)00192-0 ; Sahin (2002), The influence of functional forces on the biomechanics of implant - supported prostheses -, review J Dent, 20, 271, doi.org/10.1016/S0300-5712(02)00065-9 ; Catalfamo Formento (2014), Gait event detection during stair walking using a rate gyroscope, Sensors, 14, 5470, doi.org/10.3390/s140305470 ; Mattei (2011), Lubrication and wear modelling of artificial hip joints :, review Tribology International, 44, 532, doi.org/10.1016/j.triboint.2010.06.010 ; Jasik (2007), Methodology of estimation of the hest flow during endoprosthesoplasty Engineering of, Biomaterials, 10, 69. ; Phillips (2015), Femoral bone mesoscale structural architecture prediction using musculoskeletal and finite element modelling International, Biomechanics, 2, 1. ; Okrajni (2001), Kusz The influence of material property nonhomogenity and mode of loading on the effort of femur model components Wroclaw University of Technology Publisher, Acta Bioeng Biomech Supplement, 3, 379. ; Liu (2013), Effect of motion inputs on the wear prediction of artificial hip joints, Tribology International, 63, 105, doi.org/10.1016/j.triboint.2012.05.029 ; Stan (2014), Human gait and postural control after unilateral total knee arthroplasty MAEDICA - a Journal of Clinical, Medicine, 9, 356. ; Helgason (2008), Mathematical relationships between bone density and mechanical properties : a literature review, Clin Biomech, 23, 135, doi.org/10.1016/j.clinbiomech.2007.08.024
×