Details

Title

Bone remodelling model incorporating both shape and internal structure changes by three different reconstruction mechanisms. A lumbar spine case

Journal title

Archive of Mechanical Engineering

Yearbook

2016

Volume

vol. 63

Issue

No 4

Authors

Keywords

bone remodelling ; artificial disc ; lumbar spine ; FE analysis

Divisions of PAS

Nauki Techniczne

Coverage

549-563

Publisher

Polish Academy of Sciences, Committee on Machine Building

Date

2016.12.17

Type

Artykuły / Articles

Identifier

DOI: 10.1515/meceng-2016-0031 ; ISSN 0004-0738, e-ISSN 2300-1895

Source

Archive of Mechanical Engineering; 2016; vol. 63; No 4; 549-563

References

Homminga (2012), Can vertebra density changes be explained by intervertebral disc degeneration ? Medical Engineering, Physics, 34, 453. ; Zhu Xinghua (2002), A study of the effect of non - linearities in the equation of bone remodeling of, Journal Biomechanics, 35, 951, doi.org/10.1016/S0021-9290(02)00028-3 ; Borkowski (2012), Finite element analysis of artificial disc with an elastomeric core in the lumbar spine of and, Acta Bioengineering Biomechanics, 14, 59. ; Cunningham (2002), Total disc replacement arthroplasty using theAcroFlex lumbar disc : a non - human primate model, European Spine Journal, 11, 115. ; Telega (2004), Reconstruction of bone tissue : the evolution of concepts and models In edzinski edzior editors Biomechanics and Rehabilitation volume EXIT in Polish, Engineering. ; Wrona (2014), Computer algorithm for examination of the remodelling process in the cancellous bone Acta Bio - Optica et Informatica Medica Inzynieria in Polish, Biomedyczna, 20, 1. ; Nowak (2010), On some properties of bone functional adaptation phenomenon useful in mechanical design of and, Acta Bioengineering Biomechanics, 12, 49. ; Tkaczyk (2006), abrowska Influence of remodelling stimulating factor selection on bone density distribution in pelvic bone model of and, Acta Bioengineering Biomechanics, 8, 119. ; Borkowski (2004), edzior Numerical investigation of a new type of artificial lumbar disc of and, Journal Theoretical Applied Mechanics, 42, 253. ; Freeman (2006), Total disc replacement in the lumbar spine : a systematic review of the literature, European Spine Journal, 15, 439, doi.org/10.1007/s00586-006-0186-9 ; Lekszycki (1999), Optimality conditions in modeling of bone adaptation phenomenon of and, Journal Theoretical Applied Mechanics, 37, 607. ; Wang (2002), Simulation of bone adaptive remodeling using stochastic process as loading history of, Journal Biomechanics, 35, 375, doi.org/10.1016/S0021-9290(01)00191-9 ; Tsubota (2002), Functional adaptation of cancellous bone in human proximal femur predicted by trabecular surface remodelling simulation toward uniform stress state of, Journal Biomechanics, 35, 1541, doi.org/10.1016/S0021-9290(02)00173-2 ; Wang (2005), Evaluation of effects of selected factors on inter - vertebral fusion - a simulation study Medical Engineering &, Physics, 27, 197. ; Cunningham (2004), Basic scientific considerations in total disc arthroplasty The, Spine Journal, 4, 219, doi.org/10.1016/j.spinee.2004.07.015 ; Goel (1995), Cancellous bone Young s modulus variation within the vertebral body of a ligamentous lumbar spine - application of bone adaptive remodelling concepts of, Journal Biomechanical Engineering, 117, 266, doi.org/10.1115/1.2794180 ; Link (2002), design and biomechanics of the LINK SB Charité artificial disc, History European Spine Journal, 11, 98. ; Palissery (2009), The implications of stress patterns in the vertebral body under axial support of an artificial implant Medical Engineering &, Physics, 31, 833.
×