Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors

Tytuł czasopisma

Metrology and Measurement Systems

Rocznik

2017

Wolumin

vol. 24

Numer

No 2

Autorzy

Słowa kluczowe

fault trees ; partial discharges ; fault diagnosis ; power engineering ; power overhead lines

Wydział PAN

Nauki Techniczne

Zakres

277–288

Wydawca

Polish Academy of Sciences Committee on Metrology and Scientific Instrumentation

Data

2017.06.30

Typ

Artykuły / Articles

Identyfikator

DOI: 10.1515/mms-2017-0020 ; ISSN 2080-9050, e-ISSN 2300-1941

Źródło

Metrology and Measurement Systems; 2017; vol. 24; No 2; 277–288

Referencje

Samimi (2014), A Review on the Rogowski Coil Principles and Applications, Sensors Journal IEEE, 99. ; Misak (2015), Testing of a covered conductor s fault detectors on, IEEE Transactions Power Delivery, 30, 6957620. ; Hemmati (2012), Evaluation of unshielded Rogowski coil for measuring partial discharge signals Environment and th International Conference, Electrical Engineering, 11, 434. ; Sudha (2014), A novel approach to fault diagnosis of transmission line with Rogowski coil of, International Review Electrical Engineering, 9, 656. ; Hashmi (2010), Modeling and Experimental Verification of On - line PD Detection in MV Covered - conductor Overhead Networks, IEEE Trans, 17, 167. ; Hashmi (2011), Calibration of on - line partial discharge measuring system using Rogowski coil in covered - conductor overhead distribution networks, Science Measurement Technology IET, 5, 5. ; Isa (2012), Multi - end correlation - based PD location technique for medium voltage covered - conductor lines on Dielectrics and, IEEE Transactions Electrical Insulation, 19, 6215097. ; Misak (2010), Utilization of the Finite Element Method For Optimizing of Overhead Covered Conductors Conference, Austria. ; Hashmi (2010), Modeling and Experimental Verification of Covered - conductor for PD Detection in Overhead Distribution Networks, IEEJ Trans Power Energy, 130, 670. ; Agarwal (2014), Partially and fully insulated conductor systems for low and medium voltage overhead distribution lines Condition Assessment Techniques in Electrical Systems st International Conference, IEEE, 1, 100. ; Nobrega (2104), de Analysis of the XLPE Insulation of Distribution Covered Conductors in Brazil of Materials Engineering and Performance, Journal, 23. ; Shafiq (2013), Parameters Identification and Modeling of High - Frequency Current Transducer for Partial Discharge Measurements, Sensors Journal IEEE, 13, 1081. ; Hamacek (2013), Fault indicators of partial discharges in medium - voltage systems Advances in Electrical and, Electronic Engineering, 11, 284. ; Hashmi (2010), Effects of Rogowski Coil and Covered - Conductor Parameters on the Performance of PD Measurements in Overhead Distribution Networks Innovations, Int J Energy Syst Power, 4. ; Hemmati (2012), Evaluation of shielded Rogowski coil for measuring partial discharge signals Environment and th International Conference, Electrical Engineering, 11, 446. ; Makhkamova (2208), CFD analysis of the thermal state of an overhead line conductor Universities Power rd, Engineering Conference International, 1.

Polityka Open Access

Metrology and Measurement Systems is an open access journal with all content available with no charge in full text version.


The journal content is available under the license CC BY-NC-ND 4.0. https://creativecommons.org/licenses/by-nc-nd/4.0/
×