Nauki Techniczne

Metrology and Measurement Systems

Zawartość

Metrology and Measurement Systems | 2019 | vol. 26 | No 3

Abstrakt

In this paper methods and their examination results for automatic segmentation and parameterization of vessels based on spectral domain optical coherence tomography (SD-OCT) of the retina are presented. We present three strategies for morphologic image processing of a fundus image reconstructed from OCT scans. A specificity of initial image processing for fundus reconstruction is analysed. Then, the parameterization step is performed based on the vessels segmented with the proposed algorithm. The influence of various methods on the vessel segmentation and fully automatic vessel measurement is analysed. Experiments were carried out with a set of 3D OCT scans obtained from 24 eyes (12 healthy volunteers) with the use of an Avanti RTvue OCT device. The results of automatic vessel segmentation were numerically compared with those prepared manually by the medical doctor experts.

Przejdź do artykułu

Autorzy i Afiliacje

Tomasz Marciniak
ORCID: ORCID
Agnieszka Stankiewicz
Adam Dąbrowski
ORCID: ORCID
Marcin Stopa
Piotr Rakowicz
Elżbieta Marciniak

Abstrakt

In the paper, a procedure for precise and expedited design optimization of unequal power split patch couplers is proposed. Our methodology aims at identifying the coupler dimensions that correspond to the circuit operating at the requested frequency and featuring a required power split. At the same time, the design process is supposed to be computationally efficient. The proposed methodology involves two types of auxiliary models (surrogates): an inverse one, constructed from a set of reference designs optimized for particular power split values, and a forward one which represents the circuit S-parameter gradients as a function of the power split ratio. The inverse model directly yields the values of geometry parameters of the coupler for any required power split, whereas the forward model is used for a post-scaling correction of the circuit characteristics. For the sake of illustration, a 10-GHz circular sector patch coupler is considered. The power split ratio of the structure is re-designed within a wide range of ��6 dB to 0 dB. As demonstrated, precise scaling (with the power split error smaller than 0.02 dB and the operating frequency error not exceeding 0.05 GHz) can be achieved at the cost of less than three full-wave EM simulations of the coupler. Numerical results are validated experimentally.

Przejdź do artykułu

Autorzy i Afiliacje

Slawomir Koziel
Adrian Bekasiewicz

Abstrakt

Quality evaluation is very important for haptic rendering. In this paper, an objective evaluation method for a haptic rendering system based on haptic perception features is proposed. In the method, the haptic rendering process is compared to the real world perception process in a simple standardized procedure based on feature extraction and data analysis. A complete evaluation process for a simple haptic rendering task of pressing a virtual spring is presented as an example to explain the method in detail. Compared with the traditional objective method based on error statistics, the method is more concerned about the consistency of human subjective feelings rather than physical parameters, which makes the evaluation process more consistent with the haptic perception mechanism. The results of comparative analysis show that the method presented in this paper is simple, gives reliable results reflecting the consistency with subjective feeling and has a better discrimination ability for different kinds of devices and algorithms compared with the traditional evaluation methods.

Przejdź do artykułu

Autorzy i Afiliacje

Zhiyu Shao
Juan Wu
Qiangqiang Ouyang

Abstrakt

Dynamic angle measurement (DAM) plays an important role in precision machining, aerospace, military and artificial intelligence. Because of its advantages including high sensitivity, solid state and miniaturization, fibre-optic gyroscope (FOG) has great application prospects in the field of DAM. In this paper, we propose a dynamic angle metrology method based on FOG and a rotary table to evaluate the DAMaccuracy with FOG. The system synchronously collects data from the FOG and rotary table, and analyses the DAM accuracy of the FOG for different sway conditions compared with that of the angle obtained from the rotary table. An angle encoder in the rotary table provides absolute or incremental angular displacement output with angular displacement measurement accuracy of 10′′ (0:0028◦) and angular displacement repeat positioning accuracy of 3′′ (0:00083◦), and can be used as an angle reference. The experimental results show that the DAM accuracy of the FOG is better than 0:0028◦ obtained with the angular encoder, and the absolute DAM accuracy of the FOG is better than 0:0048◦ for given conditions. At the same time, for the multi-path signal synchronization problem in the metrology field, this paper proposes a signal delay measurement method combining test and algorithm procedures, which can control a delay within 25 μs.

Przejdź do artykułu

Autorzy i Afiliacje

Lei Chen
Yilan Zhou
Dengwei Zhang
Xiaowu Shu
Cheng Liu

Abstrakt

The single-phase voltage loss is a common fault. Once the voltage-loss failure occurs, the amount of electrical energy will not be measured, but it is to be calculated so as to protect the interest of the power supplier. Two automatic calculation methods, the power substitution and the voltage substitution, are introduced in this paper. Considering the lack of quantitative analysis of the calculation error of the voltage substitution method, the grid traversal method and MATLAB tool are applied to solve the problem. The theoretical analysis indicates that the calculation error is closely related to the voltage unbalance factor and the power factor, and the maximum calculation error is about 6% when the power system operates normally. To verify the theoretical analysis, two three-phase electrical energy metering devices have been developed, and verification tests have been carried out in both the lab and field conditions. The lab testing results are consistent with the theoretical ones, and the field testing results show that the calculation errors are generally below 0.2%, that is correct in most cases.

Przejdź do artykułu

Autorzy i Afiliacje

Han-miao Cheng
Zhong-dong Wang
Qi-xin Cai
Xiao-quan Lu
Yu-xiang Gao
Rui-peng Song
Zheng-qi Tian
Xiao-xing Mu

Abstrakt

Image segmentation is a typical operation in many image analysis and computer vision applications. However, hyperspectral image segmentation is a field which have not been fully investigated. In this study an analogue- digital image segmentation technique is presented. The system uses an acousto-optic tuneable filter, and a CCD camera to capture hyperspectral images that are stored in a digital grey scale format. The data set was built considering several objects with remarkable differences in the reflectance and brightness components. In addition, the work presents a semi-supervised segmentation technique to deal with the complex problem of hyperspectral image segmentation, with its corresponding quantitative and qualitative evaluation. Particularly, the developed acousto-optic system is capable to acquire 120 frames through the whole visible light spectrum. Moreover, the analysis of the spectral images of a given object enables its segmentation using a simple subtraction operation. Experimental results showed that it is possible to segment any region of interest with a good performance rate by using the proposed analogue-digital segmentation technique.

Przejdź do artykułu

Autorzy i Afiliacje

César Isaza
Julio M. Mosquera
Gustavo A. Gómez-Méndez
Jonny P. Zavala-De Paz
Ely Karina-Anaya
José A. Rizzo-Sierra
Omar Palillero-Sandoval

Abstrakt

We present the development of a technique for studying laser-induced magnetization dynamics, based on inductive measurement. The technique could provide a simple tool for studying laser-induced demagnetization in thin films and associated processes, such as Gilbert damping and magnetization precession. It was successfully tested using a nanosecond laser and NiZn ferrite samples and – after further development – it is expected to be useful for observation of ultra-fast demagnetization. The combination of optical excitation and inductive measurement enables to study laser-induced magnetization dynamics in both thin and several micrometre thick films and might be the key to a new principle of ultrafast broadband UV–IR pulse detection.

Przejdź do artykułu

Autorzy i Afiliacje

Tomáš Ilit’
Pavol Valko
Milan Držík
Marianna Ušáková
Martin Šoka
Marian Marton
Miroslav Behúl
Marian Vojs

Abstrakt

A navigation complex of an unmanned flight vehicle of small class is considered. Increasing the accuracy of navigation definitions is done with the help of a nonlinear Kalman filter in the implementation of the algorithm on board an aircraft in the face of severe limitations on the performance of the special calculator. The accuracy of the assessment depends on the available reliable information on the model of the process under study, which has a high degree of uncertainty. To carry out high-precision correction of the navigation complex, an adaptive non-linear Kalman filter with parametric identification was developed. The model of errors of the inertial navigation system is considered in the navigation complex, which is used in the algorithmic support. The procedure for identifying the parameters of a non-linear model represented by the SDC method in a scalar form is used. The developed adaptive non-linear Kalman filter is compact and easy to implement on board an aircraft.

Przejdź do artykułu

Autorzy i Afiliacje

Maria S. Selezneva
Konstantin A. Neusypin
Andrey V. Proletarsky

Abstrakt

The accuracy of vehicle speed measured by a speedometer is analysed. The stress on the application of skew normal distribution is laid. The accuracy of measured vehicle speed depends on many error sources: construction of speedometer, measurement method, model inadequacy to real physical process, transferring information signal, external conditions, production process technology etc. The errors of speedometer are analysed in a complex relation to errors of the speed control gauges, whose functionality is based on the Doppler effect. Parameters of the normal distribution and skew normal distribution were applied in the errors analysis. It is shown that the application of maximum permissible errors to control the measuring results of vehicle speed gives paradoxical results when, in the case of skew normal distribution, the standard deviations of higher vehicle speeds are smaller than the standard deviations of lower speeds. In the case of normal distribution a higher speed has a greater standard deviation. For the speed measurements by Doppler speed gauges it is suggested to calculate the vehicle weighted average speed instead of the arithmetic average speed, what will correspond to most real dynamic changes of the vehicle speed parameters.

Przejdź do artykułu

Autorzy i Afiliacje

Jonas Skeivalas
Eimuntas Paršeliūnas
Raimundas Putrimas
Dominykas Šlikas

Abstrakt

In this paper, we present a fibre-optic sensor for simultaneous measurement of refractive index and thickness of liquid layers.We designed an experimental low-coherence setup with two broadband light sources and an extrinsic fibre-optic Fabry–Pérot interferometer acting as the sensing head.We examined how the refractive index of a liquid film and its thickness affect spectrum at the output of a fibre-optic interferometer. We performed a series of experiments using two light sources and only one sensing head. The spectra were collected in ranges of 1220÷1340 nm and 1500÷1640 nm. The obtained results show that using two spectra recorded simultaneously for two wavelength ranges enables to determine thickness in a range of 50÷500 μm, and refractive index of a liquid film in a range of 1:00÷1:41 RIU using only one sensing head.

Przejdź do artykułu

Autorzy i Afiliacje

Marcin Marzejon
Katarzyna Karpienko
Adam Mazikowski
Małgorzata Jędrzejewska-Szczerska

Abstrakt

A ship built from ferromagnetic steel disturbs the uniformity of the Earth’s magnetic field. Changes of ship’s signature are due to the magneto-mechanical interaction of the hull with the Earth’s magnetic field. The ship’s magnetic field can be detected by a magnetic naval mine. For this reason, the vessel has to be demagnetized. There are several methods of ship’s de-perming. The results of experimental and computer simulations of the ship’s de-perming process using coils lying on the seabed are presented in this paper. The simulation of the de-perming process with a hysteresis model of ship’s steel was carried out in Opera-3d 18R2. The laboratory experiments were carried out using a physical ship’s model, several Helmholtz coils, magneto-resistive sensors, etc. The experiments and computer simulations have shown that ship’s de-perming with coils lying on the seabed is possible. The values of coil currents are over dozen times greater than those used in the standard method.

Przejdź do artykułu

Autorzy i Afiliacje

Mirosław Wołoszyn
Piotr Jankowski

Abstrakt

In this article, we study tilted fiber Bragg gratings (TFBGs) with tilt angles of 6◦ and 8◦, their transmission spectra, and spectral parameters that have a linear dependence on the refractive index of the environment. It is shown that there can be several such characteristics, such as the minimum, width and energy of the spectrum. The linear dependence of the spectrum width on the refractive index does not depend on the tilt angle. The linear dependence of the spectrum minimum is only observed for a tilt angle of 8◦. The results of this work can be used to create a sensor system based on an optical fiber.

Przejdź do artykułu

Autorzy i Afiliacje

Akmaral Tolegenova
Piotr A. Kisała
Ainur Zhetpisbayeva
Orken Mamyrbayev
Bekbolat Medetov

Instrukcja dla autorów



Sample article with Author guidelines



Author guidelines



Types of contributions

Metrology and Measurement Systems welcomes submissions of the following article types:

• invited special issue or review papers presenting the current stage of the knowledge within scope of the journal (about 20 edited pages, approximately 3000 characters each),
• research papers reporting high-quality original scientific or technological advancements (max. 12 pages),
• papers based on extended and updated contributions presented at scientific conferences (max. 12 pages),
• short notes, i.e. book reviews, conference reports, short news (max. 2 pages).


Manuscript preparation

General The text of a manuscript should be written in clear and concise English. The camera-ready format – with attached separate files containing illustrations, tables and photographs – is required. A cover letter with clear explanation of scientific novelty of the paper is strongly recommended. Papers based on extended and updated contributions presented at scientific conferences, or strongly related to previous authors’ works, must be accompanied with a cover letter file, which should explain in details changes made in the manuscript in comparison with the original conference paper and highlight the novelty in reference to other authors’ works.
The main text of a manuscript should be printed on an A4 page (with margins of 2.5 cm) using Times New Roman style with a font size of 12 pt; the paragraphs should start with the indentation of 5 mm, and titles should be written in bold. That text can be divided into sections (numbered 1, 2, …), first-order subsections (numbered 1.1., 1.2., …, written in italics), and – if needed – second-order subsections (numbered 1.1.1., 1.1.2., …, written same as first-order subsections). The only acceptable manuscript formats are in Microsoft Word (.doc, .docx).

The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors. The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors.


Figures
Figures (illustrations, photographs) and tables, provided in the camera-ready form suitable for reproduction (which may include reduction), should be additionally submitted (one per page), larger than the final size. While preparing figures we encourage to start with defining expected size and minimum font size that fit to all graphics in the manuscript – using the same style in all of your graphics visually improves the article. Final figure formats must be in one of the following: (vectors) .eps, .pdf, .ai or .cdr, and (bitmaps) .bmp, .gif, .tif or .jpg.
As far as plots, block diagrams, schematics etc. are concerned, we suggest to use one of vector formats to improve quality and scalability. Figures in vector formats must be saved using RGB colours and with fully white background (0% K). Hidden layers are unacceptable. Minimum line thickness printed in a single colour is 0.25 pt (0.09 mm), and 1 pt (0.36 mm) when using more colours. Typically we suggest 0.2-0.5 mm but in particular cases the range 0.1–1.0 mm will be accepted. Lines in plots should be distinguished not only by using different colours but also using different line types and markers, if needed.


Equation
All equations must be numbered consecutively throughout the text. Each equation should be preceded and followed by a 6-point spacing. Punctuate equations when they are part of a sentence. Equation numbers should be enclosed in parentheses. Equations should be prepared with the use of MathType or Microsoft Equation editors. The type size in the equation is the same as for the text. To make your equations more compact, you may use the appropriate mathematical symbols or expressions. The symbols used in an equation have to be defined before that equation or immediately after it. Use italics for variables (e.g. i, x, n), physical quantity symbol (e.g. voltage U, temperature T), letter pointers and general function symbols. Do not use italics for constants, indexes, minimum, maximum and trigonometric functions, mathematical operators, differentials, etc. To refer to the equation use “(1)”, not “Eq. (1)” or “equation (1)”, except at the beginning of a sentence where “Equation (1)” should be used. We recommend to use International System of Units SI i.e. metre-kilogram-second system of units. As a decimal separator dot should be used in the entire manuscript (text, figures, tables).


References
The paper has to be clearly positioned in the context of relevant literature in the field of measurements and instrumentation. Note that lack of references from the main field of Metrology and Measurement Systems interest may suggest that the content of manuscript does not exactly correspond to the scope of metrological journals. It may reduce possibility that a proposed paper will be read by audience society. In such a case our Editorial Board may suggest to send the manuscript to a more appropriate journal. Also note that the use of possibly up-to-date references may indicate importance of your work. Table below gives examples of some relevant and renewable journals related to widely understood metrology.


Journal

Publisher

ISSN

Metrologia

IOP Publishing

0026-1394

IEEE Transactions on Instrumentation and Measurement

IEEE

0018-9456

Measurement

Elsevier

0263-2241

Measurement Science and Technology

IOP Publishing

0957-0233

Metrology and Measurement Systems

PAS

0860-8229

Review of Scientific Instruments

IOP Publishing

0034-6748

IEEE Transactions on Industrial Electronics

IEEE

1557-9948

IET Science, Measurement & Technology

IET

1751-8822

Journal of Instrumentation

SISSA, IOP Publishing

1748-0221

Measurement Science Review

Walter de Gruyter

1335-8871

IEEE Instrumentation and Measurement Magazine

IEEE

1094-6969

Bulletin of the Polish Academy of Sciences: Technical Sciences

PAS

2300-1917

Opto-Electronics Review

PAS

1896-3757

IEEE Sensors Journal

IEEE

1558-1748

Sensors

MDPI

1424-8220




References should be inserted in the text in square brackets, i.e. [1]; their list, numbered in citation order, should appear at the end of the manuscript. The format of the references should follow the APA 7th edition formatting style, i.e.: for an journal paper – surname(s) and initial(s) of author(s), year in brackets, title of the paper, full journal name, volume, issue (in brackets) and page numbers. Put all author names unless there are more than 20. Otherwise, after the first 19 authors’ names, use an ellipsis in place of the remaining author names. Then, end with the final author’s name (do not place an ampersand before it).


Submission process
Manuscript should be submitted via the Internet Editorial System (IES) – an online submission and peer review system. In order to submit the manuscript via the IES, the authors (first-time users) must create an author account to obtain a user ID and password required to enter the system. The submission of the manuscript in a single file, i.e. “Article File” containing the complete manuscript (with all figures of high quality and tables embedded in the text), is preferred. All figures have to be uploaded in separate files. The generated PDF file has to be approved. The PDF file has lower quality of the embedded figures to limit its size only.
The submission of a manuscript means that its content has not been published previously, it is not under consideration for publication elsewhere, and that – if accepted – it will not be published elsewhere. The Author hereby grants the Polish Academy of Sciences (the Journal Owner) the license for commercial use of the article according to the Open Access License ( CC BY-NC-ND 4.0), which has to be signed before publication. The copyright form is available in the IES.
The Authors are urged to suggest 4 to 5 reviewers in their application (with names, affiliations and addresses) with whom the Editorial Board could co-operate while processing the paper. Proposed reviewers should be experts deeply involved in issues related to the subject matter of the paper and they are intended to come from different universities or research centres.
Each submitted manuscript is subject to a single-blind peer-review procedure, and the publication decision is based on the reviewers’ comments. If necessary, the authors may be invited to revise their manuscripts. On acceptance, manuscripts are subject to editorial amendment to exactly fit the journal style.
An essential criterion for the evaluation of submitted manuscripts is their potential impact on the research field, measured by the number of repeated quotations. Such papers are preferred at the evaluation and publication stages.
Proofs will be sent to the corresponding author by e-mail and should be returned within 48 hours from receipt. The publication in the journal is free of charge. A sample copy of the journal will be sent to the corresponding author free of charge. For colour pages the authors will be charged at the rate of 160 PLN or 80 EUR per page. The payment to the bank account of the main distributor (given in “Subscription Information”) must be completed before the date indicated by the Editorial Office.


Other information
It is possible to include supplementary files related to the article content, such as e.g. developed databases. These files can be then used by other researchers to compare their algorithms using the same input data. For more details about supplementary files please contact the Editorial Board: metrology@wat.edu.pl. The biographical statements, at the very end of the article, are not obligatory, however, they are kindly recommended. Each statement should include the author’s full name and brief personal history focused on areas of research and scientific achievements. The biographical statement may not exceed 100 words and should be written using Times New Roman style with a font size of 8 pt.
The publication of your article is a great achievement but then it needs to be further promoted to make it more visible to the research community. Responsibility for this task lies with the Authors and our Editorial Board. We guarantee free access to the article in the Journals PAN of the Polish Academy of Science, including articles in Early Access form (published just after acceptance decision), indexing in popular and renewable databases (e.g. Thomson Scientific Master Journal List, Elsevier’s Scopus, Google Scholar). Furthermore, selected articles are highlighted on the journal website and are reprinted for promotion at conferences and other events. The Authors can share the final form of the article on various social networks and research-sharing platforms, such as Twitter, Facebook, Linkedin, ResearchGate, Academia.edu, SciProfiles. They are also encouraged to update personal and institutional webpages by adding the title and a link of the article. Feel free also to share your work with your colleagues using any other methods that do not conflict with the CC BY-NC-ND 4.0 license.
For more detailed description about how to write a paper for the Metrology and Measurement Systems journal please look at the Author guidelines for manuscript preparation. We strongly recommend using this file as a template for manuscript preparation.


Ta strona wykorzystuje pliki 'cookies'. Więcej informacji