Wyniki wyszukiwania

Filtruj wyniki

  • Czasopisma
  • Autorzy
  • Słowa kluczowe
  • Data
  • Typ

Wyniki wyszukiwania

Wyników: 4
Wyników na stronie: 25 50 75
Sortuj wg:

Abstrakt

In a parallel time-interleaved data sampling system, timing and amplitude mismatches of this structure degrade the performance of the whole ADC system. In this paper, an adaptive blind synthesis calibration algorithm is proposed, which could estimate the timing, gain and offset errors simultaneously, and calibrate automatically. With no need of an extra calibration signal and redesign, it could efficiently and dynamically track the changes of mismatches due to aging or temperature variation. A fractional delay filter is developed to adjust the timing mismatch, which simplifies the design and decreases the cost. Computer simulations are also included to demonstrate the effectiveness of the proposed method.

Przejdź do artykułu

Autorzy i Afiliacje

Huiqing Pan
Shulin Tian
Peng Ye

Abstrakt

The main purpose of the article is to develop a multifactorial model for rapid assessment of the efficiency of biological wastewater treatment reactors. A mathematical model of the process of biological wastewater treatment has been developed based on: changes in the concentration of organic contaminants in the bioreactor over time, taking into account the uneven flow of wastewater to the treatment plant, the process of substrate entering the bioreactor (different amounts may enter at different times). The software implementation of the proposed algorithm for solving the corresponding model problem in Python is carried out. The results of computer experiments on the study of the efficiency of wastewater treatment in biological treatment reactors for different operating conditions of facilities are presented. In particular, such processes were considered with taking into account the unevenness of the load, because the maximum cleaning loads are in the morning and in the evening. The task was solved to simulate a real situation and show how cleaning takes place at the maximum load at a certain time of the day. The results obtained will be useful for calculations in the design of biological treatment facilities or in the reconstruction of existing bioreactors for their prospective operation under new operating conditions.
Przejdź do artykułu

Autorzy i Afiliacje

Andrii Safonyk
1
ORCID: ORCID
Oleg Rogov
1
ORCID: ORCID
Maksym Trokhymchuk
1
ORCID: ORCID
Olena Prysiazhniuk
1
ORCID: ORCID
Ihor Prysiazhniuk
2
ORCID: ORCID

  1. National University of Water and Environmental Engineering, Institute of Energy, Automatics and Water Management, Department of Automation, Electrical Engineering and Computer-integrated Technologies, 11 Soborna St, 33028, Rivne, Ukraine
  2. Rivne State University of Humanities, Faculty of Mathematics and Informatics, 31 Plastova St, 33000, Rivne, Ukraine

Abstrakt

In this paper the capacity of non-uniform sampling rate conversion techniques, involving different interpolation methods, aimed at wow defect reduction, is examined. Involved are: linear interpolation, four polynomial-based interpolation methods and the windowed sincbased method. The examined polynomial methods are: Lagrange interpolation, polynomial fitting with additional noise reduction, Hermitan and Spline. The performance of an artificially distorted audio signal, restored using non-uniform resampling, is evaluated on the basis of standard audio defect measurement criteria and compared for all of the aforementioned interpolation methods. The chosen defect descriptors are: total harmonic distortion, total harmonic distortion plus noise and signal to noise ratio.

Przejdź do artykułu

Autorzy i Afiliacje

P. Maziewski

Abstrakt

The present work is aimed at geometrical optimization and optical analysis of a small-sized parabolic trough collector (PTC). Improving the performance of parabolic trough collectors can greatly justify the use of solar energy. An optimized curvature geometry, the location of the absorber tube, and the heat flux distribution along the circumference of the absorber tube are major features in the geometric optimization and optical modelling of parabolic trough collectors. Rim angle, aperture width, the diameter of the absorber tube, receiver position, and the optimum value of heat flux are the major parameters considered in this work for geometrical and optical analysis. The Monte Carlo ray tracing method has been adopted for analysis. The non-uniform heat flux distribution profile obtained from optical analysis of the proposed parabolic trough collector has been compared with the profile available in the literature, and good agreement has been obtained, which proves the feasibility and reliability of the model and method used for this study. An experimental new small-sized parabolic trough collector has been fabricated for the optimized rim angle of 90 deg after a successful laser light feasibility test. The effect of the absorber tube position along the optical axis on the heat flux profile was analysed and found to be substantial. Furthermore, the sensitivity analysis of the parabolic trough collector using the software applied has been discussed separately.
Przejdź do artykułu

Autorzy i Afiliacje

Raman Kumar Singh
1
Prakash Chandra
1

  1. National Institute of Technology Patna, Department of MechanicalEngineering, Bihar 800005, India

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji