In the paper, the results of numerical simulations of the steam flow in a shell and tube heat exchanger are presented. The efficiency of different models of turbulence was tested. In numerical calculations the following turbulence models were used: k-ε, RNG k-ε, Wilcox k-ω, Chen-Kim k-ε, and Lam-Bremhorst k-ε. Numerical analysis of the steam flow was carried out assuming that the flow at the inlet section of the heat exchanger were divided into three parts. The angle of steam flow at inlet section was determined individually in order to obtain the best configuration of entry vanes and hence improve the heat exchanger construction. Results of numerical studies were verified experimentally for a real heat exchanger. The modification of the inlet flow direction according to theoretical considerations causes the increase of thermal power of a heat exchanger of about 14%.
Work on increasing the efficiency of heat exchangers used in car air conditioning systems may lead to a partial change in the construction of refrigeration systems. One of such changes is the use of smaller gas coolers, which directly translates into a reduction in the production costs of the entire system. The article presents the use of computational fluid dynamics methods to simulate the impact of changing the shape of an internal heat exchanger on the cooling efficiency with R744 as the refrigerant. Internal heat exchangers with different geometry of the outer channels were subjected to numerical analysis. The obtained results of calculations show temperature changes in inner and outer channels on the length of the heat exchanger.
Plate fin-tube heat exchangers fins are bonded with tubes by means of brazing or by mechanical expansion of tubes. Various errors made in the process of expansion can result in formation of an air gap between tube and fin. A number of numerical simulations was carried out for symmetric section of plate fin-tube heat exchanger to study the influence of air gap on heat transfer in forced convection conditions. Different locations of air gap spanning 1/2 circumference of the tube were considered, relatively to air flow direction. Inlet velocities were a variable parameter in the simulations (1– 5 m/s). Velocity and temperature fields for cases with air gap were compared with cases without it (ideal thermal contact). For the case of gap in the back of the tube (in recirculation zone) the lowest reduction (relatively to the case without gap) of heat transfer rate was obtained (average of 11%). The worst performance was obtained for the gap in the front (reduction relatively to full thermal contact in the average of 16%).
An attempt was made to determine the vertical momentum and heat exchange in the near-ground atmosphere layer in the specific conditions of a sub-Antarctic island. For this purpose, some of the results of the measurements of temperature and wind speed carried out at the levels 10, 2, 0.5 and 0.05 m, during the IVth Antarctic Expedition of the Polish Academy of Sciences in March 1980, were used. The vertical gradients of the two elements and the wind stress and the heat flux in the layers under study, were calculated.
On the basis of the results of direct measurements, the conduction properties of the yearly behaviour of the halt flux conducted in the tundra soil (S) are determined. In general, the cooling period of the soil profile lasted from August to January, with highest intensity in October (S = —4.8 Wm-2). A rapid intensification of the heat exchange in the soil occurred in July (S = 7.4 Wm-2 ) . The 24-hour values of S were found to vary greatly (from 19 Wm-2 to 32 Wm-2). For chosen days, relationships were determined among the particular elements of the heat balance of the active layer.
The objective of the study reported in this paper was to determine the effect of structure on thermal power of cast-iron heat exchangers which in this case were furnace chambers constituting the main component of household fireplace-based heating systems and known commonly as fireplace inserts. For the purpose of relevant tests, plate-shaped castings were prepared of gray iron with flake graphite in pearlitic matrix (the material used to date typically for fireplace inserts) as well as similar castings of gray cast iron with vermicular graphite in pearlitic, ferritic-pearlitic, and ferritic matrix. For all the cast iron variants of different structures (graphite precipitate shapes and matrix type), calorimetric measurements were carried out consisting in determining the heat power which is quantity representing the rate of heat transfer to the ambient environment. It has been found that the value of the observed heat power was affected by both the shape of graphite precipitates and the type of alloy matrix. Higher thermal power values characterize plate castings of gray iron with vermicular graphite compared to plates cast of the flake graphite gray iron. In case of plates made of gray cast iron with vermicular graphite, the highest values of thermal power were observed for castings made of iron with ferritic matrix.
The theoretical basis for the indirect measurement approach of mean heat transfer coefficient for the packed bed based on the modified single blow technique was presented and discussed in the paper. The methodology of this measurement approach dedicated to the matrix of the rotating regenerative gas heater was discussed in detail. The testing stand consisted of a dedicated experimental tunnel with auxiliary equipment and a measurement system are presented. Selected experimental results are presented and discussed for selected types of matrices of regenerative air preheaters for the wide range of Reynolds number of gas. The agreement between the theoretically predicted and measured temperature profiles was demonstrated. The exemplary dimensionless relationships between Colburn heat transfer factor, Darcy flow resistance factor and Reynolds number were presented for the investigated matrices of the regenerative gas heater.
This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.
Słowa kluczowe
An approach – relaying on application of nanofluid as a working fluid, to improve performance of the two-phase thermosyphon heat exchanger (TPTHEx) has been proposed. The prototype heat exchanger consists of two horizontal cylindrical vessels connected by two risers and a downcomer. Tube bundles placed in the lower and upper cylinders work as an evaporator and a condenser, respectively. Distilled water and nanofluid water-Al2O3solution were used as working fluids. Nanoparticles were tested at the concentration of 0.01% and 0.1% by weight. A modified Peclet equation and Wilson method were used to estimate the overall heat transfer coefficient of the tested TPTHEx. The obtained results indicate better performance of the TPTHEx with nanofluids as working fluid compared to distilled water, independent of nanoparticle concentration tested. However, increase in nanoparticle concentration results in overall heat transfer coefficient decrease of the TPTHEx examined. It has been observed that, independent of nanoparticle concentration tested, decrease in operating pressure results in evaporation heat transfer coefficient increase.
In the paper a heating system with a vapour compressor heat pump and vertical U-tube ground heat exchanger for small residential house is considered. A mathematical model of the system: heated object - vapour compressor heat pump - ground heat exchanger is presented shortly. The system investigated is equipped, apart from the heat pump, with the additional conventional source of heat. The processes taking place in the analyzed system are of unsteady character. The model consists of three elements; the first containing the calculation model of the space to be heated, the second - the vertical U-tube ground heat exchanger with the adjoining area of the ground. The equations for the elements of vapour compressor heat pump form the third element of the general model. The period of one heating season is taken into consideration. The results of calculations for two variants of the ground heat exchanger are presented and compared. These results concern variable in time parameters at particular points of the system and energy consumption during the heating season. This paper presents the mutual influence of the ground heat exchanger subsystem, elements of vapour compressor heat pump and heated space.
The recently developed special unity Mach number dispersion model prescribes the corrections to heat transfer coefficients which are simple functions of the dispersive Peclet numbers. They can be determined through the residence time measurements. An evaluation method is described in which the measured input and response concentration profiles are numerically Laplace transformed and evaluated in the frequency domain. A characteristic mean Peclet number is defined. The method is also applied to the parabolic dispersion model and the cascade model. A calculated example of a tube bundle with maldistribution and backflow demonstrates the suitability of the evaluation method.
Analysis of the state of-the-art in research of minichannel heat exchangers, especially on the topic of flow maldistribution in multiple channels, has been accomplished. Studies on minichannel plate heat exchanger with 51 parallel minichannels with four hydraulic diameters, i.e., 461 μm, 574 μm, 667 μm, and 750 μm have been presented. Flow at the instance of filling the microchannel with water at low flow rates has been visualized. The pressure drop characteristics for single minichannel plate have been presented along with the channels blockage, which occurred in several cases. The impact of the mass flow rate and channels’ cross-section dimensions on the flow maldistribution were illustrated.
The paper presents four 1-dimensional models of thermal resistance of walls in a heat exchanger with rectangular minichannels. The first model is the simplest one, with a single wall separating two fluids. The second model of the so called equivalent wall takes into account total volume of intermediate walls between layers of minichannels and of side walls of minichannels. The next two more complicated models take separately into account thermal resistance of these walls. In these two models side walls are treated as fins. The results of models comparison are presented. It is shown that thermal resistance may be neglected for metal walls but it should be taken into account for the walls made of plastics. For the case of non-neglected wall thermal resistance the optimum wall thickness was derived. Minichannel heat exchangers made of plastic are larger than those built of metal, but are significantly cheaper. It makes possible to use of such exchangers in inexpensive microscale ORC installations.
Analysis of the state of-the-art in research of refrigerant condensation in miniature heat exchangers, so-called multiports, was made. Results of refrigerant R407C condensation in a mini condenser made in the form of two bundles of tubular minichannels from stainless steel with an inside diameter 0.64 mm and length 100 mm have been presented. Two exchangers consisted of four minichannels and 8 minichannels have been investigated. The values of average heat transfer coefficient and frictional pressure drops throughout the condensation process were designated. The impact of the vapor quality of refrigerant and the mass flux density on the intensity of heat transfer and flow resistance were illustrated. A comparative analysis of test results for various refrigerants in both mini heat exchangers were made.
Heat exchangers of different types find application in power systems based on solid oxide fuel cells (SOFC). Compact plate fin heat exchangers are typically found to perfectly fit systems with power output under 5 kWel. Micro-combined heat and power (micro-CHP) units with solid oxide fuel cells can exhibit high electrical and overall efficiencies, exceeding 85%, respectively. These values can be achieved only when high thermal integration of a system is assured. Selection and sizing of heat exchangers play a crucial role and should be done with caution. Moreover, performance of heat exchangers under variable operating conditions can strongly influence efficiency of the complete system. For that reason, it becomes important to develop high fidelity mathematical models allowing evaluation of heat exchangers under modified operating conditions, in high temperature regimes. Prediction of pressure and temperatures drops at the exit of cold and hot sides are important for system-level studies. Paper presents dedicated mathematical model used for evaluation of a plate fin heat exchanger, operating as a part of micro-CHP unit with solid oxide fuel cells.
A mathematical model of the steam superheater exchanger with distributed parameters has been developed. Scale deposits were assumed to be present on the internal tube surfaces. It was assumed that the inner tube surfaces are covered by a thin layer of scale deposits. The finite volume method was used to solve partial differential equations describing flue gas, tube wall and steam temperature. The developed modeling technique can especially be used for modeling tube heat exchangers when detail information on the tube wall temperature distribution is needed. The numerical model of the superheater developed in the paper can be used for modeling of the superheaters with complex flow arrangement accounting scales on the internal tube surfaces. Using the model proposed the detailed steam, wall and flue gas temperature distribution over the entire superheater can be determined. The steam pressure distribution along its path flow and the total heat transfer rate can also be obtained. The calculations showed that the presence of scale on the internal surfaces of the tubes cause the steam temperature decrease and the heat flow rate transferred from the flue gas to the steam. Scale deposits on the inner surfaces of the tubes cause the tube wall temperature growth and can lead to premature wear of tubes due to overheating.