The analysis of mechanical behaviour of spinal column is until now still a challenge, in spite of the great amount of research which has been conducted over the last years. It is a particularly complex structure considering number of components, their shapes and mechanical characteristics. The objectives of the presented investigations are to understand the mechanisms of the mechanical behaviour of the spine structure and the role of its components, as well as the factors of its dysfunctions as scoliosis discopathy, spondylolisthesis. Also some mechanical effects of surgical interventions by total disc replacement is considered. To account for the 3D character of the spine system including vertebrae, discs, ligaments, muscles etc. the finite element method (FEM) formulation was used throughout the paper. Some specific features of the structure are included in the models as non-conservative loads and muscular tension control performed by the nervous system. The finite element method together with CAD programs and experimental validation was used in investigations of a new type of artificial disc for lumbar spine. The stress analyses were performed for the prostheses being in clinical use and for some original new designs. The conclusions concern most important determinants of the mechanical behaviour of the system and the quality of the intervertebral disc prosthesis.
In this simulation study, we used an anatomical computer model of the human ventricles to simulate body surface potentials and magnetic field for 10 single preexcitation sites and 8 pairs of preexcitation sites positioned on the epicardial surface along the atrio-ventricular ring. We demonstrated that electrocardiographic and magnetocardiographic inverse solutions using a pair of equivalent dipoles could be employed in localising dual accessory pathways. Average localisation errors were in the range of 5 to 21 mm and 3 mm to 20 mm, respectively, when body surface potentials and magnetic field were used. Additionally, we have investigated the influence of random lead displacements and limited lead selection on localisation results.
High resolution body surface potential maps and an equivalent current dipole model of the cardiac generator were used to assess the heart state in two abnormal conditions: WPW syndrome with single accessory pathway and local ventricular ischemia. Results of a simulation study and experimental verification of the method for both cardiologic abnormalities are presented. Single accessory pathway in WPW syndrome was simulated as initial ventricular activation at the atrio-ventricular ring. Using a current dipole model of the cardiac generator, the locus of arrhythmogenic tissue was assessed with a mean error of 11 mm. Experimental localization of the accessory pathway in a WPW patient was in good agreement with the invasively obtained site. Local repolarization changes were simulated as shortening of the myocytes action potentials in three regions typical for stenosis of main coronary arteries. Using surface QRST integral maps and dipolar source model, small subendocardial and subepicardial lesions of myocardium were inversely located with a mean error of 9 mm and larger transmural lesions with a considerable mean error of 17 mm. Extent and prevalence of subepicardial or subendocardial type of the lesion were reflected in the dipole moment and orientation. In experimental verification of the method, in 7 of 8 patients that underwent PCI of a single vessel, estimated equivalent current dipole position matched well the treated vessel. The results suggest that diagnostic interpretation of body surface potential maps based on dipolar source model could be a useful tool to assess local pathological changes in the heart.
The propagation of EEG activity during the Continuous Attention Test (CAT) was determined by means of Short-time Directed Transfer Function (SDTF). SDTF supplied the information on the direction, spectral content and time evolution of the propagating EEG activity. The differences in propagation for target and non-target conditions were found mainly in the frontal structures of the brain.
Purpose: to demonstrate the possibility of finding features reliable for more precise distinguishing between normal and abnormal Pattern Electroretinogram (PERG) recordings, in Continuous Wavelet Transform (CWT) coefficients domain. To determine characteristic features of the PERG and Pattern Visual Evoked Potential (PVEP) waveforms important in the task of precise classification and assessment of these recordings. Material and methods: 60 normal PERG waveforms and 60 PVEPs as well as 47 PERGs and 27 PVEPs obtained in some retinal and optic nerve diseases were studied in the two age groups (<= 50 years, > 50 years). All these signals were recorded in accordance with the guidelines of ISCEV in the Laboratory of Electrophysiology of the Retina and Visual Pathway and Static Perimetry, at the Department and Clinic of Ophthalmology of the Pomeranian Medical University. Continuous Wavelet Transform (CWT) was used for the time-frequency analysis and modelling of the PERG signal. Discriminant analysis and logistic regression were performed in statistical analysis of the PERG and PVEP signals. Obtained mathematical models were optimized using Fisher F(n1; n2) test. For preliminary evaluation of the obtained classification methods and algorithms in clinical practice, 22 PERGs and 55 PVEPs were chosen with respect to especially difficult discrimination problems (“borderline” recordings).
Results: comparison between the method using CWT and standard time-domain based analysis showed that determining the maxima and minima of the PERG waves was achieved with better accuracy. This improvement was especially evident in waveforms with unclear peaks as well as in noisy signals. Predictive, quantitative models for PERGs and PVEPs binary classification were obtained based on characteristic features of the waveform morphology. Simple calculations algorithms for clinical applications were elaborated. They proved effective in distinguishing between normal and abnormal recordings.
Conclusions: CWT based method is efficient in more precise assessment of the latencies of the PERG waveforms, improving separation between normal and abnormal waveforms. Filtering of the PERG signal may be optimized based on the results of the CWT analysis. Classification of the PERG and PVEP waveforms based on statistical methods is useful in preliminary interpretation of the recordings as well as in supporting more accurate assessment of clinical data.
The electrical impedance diagnostic methods and instrumentation developed at the Gdansk and Warsaw Universities of Technology are described. On the basis of knowledge of their features, several original approaches to the broad field of electrical impedance applications are discussed. Analysis of electrical field distribution after external excitation, including electrode impedance, is of primary importance for measurement accuracy and determining the properties of the structures tested.
Firstly, the problem of electrical tissue properties is discussed. Particular cells are specified for in vitro and in vivo measurements and for impedance spectrometry. Of especial importance are the findings concerning the electrical properties of breast cancer, muscle anisotropy and the properties of heart tissue and flowing blood. The applications are both important and wide-ranging but, for the present, special attention has been focused on the evaluation of cardiosurgical interventions.
Secondly, methods of instrument construction are presented which use an electrical change in conductance, such as impedance pletysmography and cardiography, for the examination of total systemic blood flow. A new method for the study of right pulmonary artery blood flow is also introduced. The basic applications cover examination of the mechanical activity of the heart and evaluation of many haemodynamic parameters related to this. Understanding the features that occur during blood flow is of major importance for the proper interpretation of measurement data.
Thirdly, the development of electrical impedance tomography (EIT) is traced for the purposes of determining the internal structure of organs within the broad field of 2-D and 3-D analysis and including modelling of the organs being tested, the development of reconstruction algorithms and the construction of hardware.
Biosensors are a crucial part of most of bioanalytical diagnostic devices and systems. Due to semiconductor technologies, a great progress in diminution of costs and miniaturisation as well as an increased reliability of these devices was achieved. Application of
molecular and biological techniques in the detection process has contributed to a real increase in sensitivity, selectivity, the detection limit and the number of analytes to be detected. Different transducers of chemical parameters into electrical output signals are applied in these devices. Electrochemical principles, both potentiometric and amperometric, are opted for due to their simplicity of application and extremely low costs of such biosensors. Ion sensitive field effect transistors (ISFETs) may be easily integrated into the required electronics, resulting in their miniaturisation. Further miniaturisation may be attained by development of miniaturised total analytical systems (uTAS). To ensure competitive parameters of these biosensors, optimal methods of immobilisation of biochemical receptors (ionophores, enzymes, antibodies, etc.) should be developed. A review of the work by the authors related to these problems is presented in the article.
Sol-gel derived silica possess many promising features, including low-temperature preparation procedure, porosity, chemical and physical stability. Applications exploiting porous materials to encapsulate sensor molecules, enzymes and many other compounds, are developing rapidly. In this paper some potential applications, with emphasis on biomedical and environmental ones, are reviewed. The material preparation procedure is described and practical remarks on silica-based sol-gels are included. It is reported that sol-gels with entrapped various molecules may be used in construction of implants and coatings with bioactive properties. It is shown how to exploit the sol-gel production route for construction of sol-gel coated fiberoptic applicators for lasertherapy. The applications of bioactive materials are discussed, as well. It is demonstrated that it is possible to immobilize photosensitive compounds in sol-gel matrix without loosing their photoactivity. Some examples of sol-gel based biosensors are demonstrated, as well, showing their potential for detecting various gases, toxic substances, acidity, humidity, enzymes and biologically active agents.
Despite the considerable progress that has recently been made in medicine, the treatment of viral infections is still a problem remaining to be solved. This especially concerns infections caused by newly emerging patogenes such as: human immunodeficiency virus, hepatitis C virus or SARS-coronavirus. There are several lines of evidence that the unusual genetic polymorphism of these viruses is responsible for the observed therapeutic difficulties. In order to determine whether some parameters describing a very complex and variable viral population can be used as prognostic factors during antiviral treatment computational methods were applied. To this end, the structure of the viral population and virus evolution in the organisms of two patients suffering from chronic hepatitis C were analyzed. Here we demonstrated that phylogenetic trees and Hamming distances best reflect the differences between virus populations present in the organisms of patients who responded positively and negatively to the applied therapy. Interestingly, the obtained results suggest that based on the elaborated method of virus population analysis one can predict the final outcome of the treatment even before it has started.
Optimization of dialysis needs methods for quantitative assessment of fluid and solutes transport in body compartments and solute
and fluid exchange between body and dialysate. A mathematical model describing the dynamics of these quantities during dialysis is presented. This model is first and foremost based on the existing models, but also includes some new solutions. All parts were combined and extended by the detailed descriptions of selected aspects. The “virtual patient” model was applied to simulate and test different methods of treatment and their influence on the condition of the patient. The purpose of this model is to serve as a decision support system for selection of “optimal” treatment options for particular patient.
The positive (minimal) realization problem for a class of singular discrete-time linear single-input, single-output systems with delays in state and delays in control is addressed. Solvability conditions for the positive (minimal) realization problem are established. It is shown that there exists a positive (minimal) realization of an improper transfer function T(z) = n(z) / d(z) if the coefficients of polynomial n(z) are non-negative and of the polynomial d(z) are non-positive except the leading one, which should be positive. A procedure for computation of the positive (minimal) realization of the transfer function is proposed and illustrated by an example.
Guide for Authors
https://www.editorialsystem.com/bpasts/journal/for_authors/
Guide for Reviewers
https://www.editorialsystem.com/bpasts/journal/for_reviewers/
Call for Papers
https://www.editorialsystem.com/bpasts/journal/call_for_papers/
Guide for Guest Editors
https://www.editorialsystem.com/editor/bpasts/journal/page1/