Details Details PDF BIBTEX RIS Title Virtual and material models of human thoracic-lumbar spine with compressive fracture based on patients' CT data and the rapid prototyping technique Journal title Archive of Mechanical Engineering Yearbook 2011 Volume vol. 58 Issue No 4 Authors Dąbrowska-Tkaczyk, Anna ; Floriańczyk, Anna ; Grygoruk, Roman ; Skalski, Konstanty ; Borkowski, Piotr Keywords thoracic-lumbar spine segment ; vertebra compressive fracture ; computer tomography ; CT ; virtual 3D-CAD model ; rapid prototyping ; RP ; material model Divisions of PAS Nauki Techniczne Coverage 425-440 Publisher Polish Academy of Sciences, Committee on Machine Building Date 2011 Type Artykuły / Articles Identifier DOI: 10.2478/v10180-011-0026-2 ; ISSN 0004-0738, e-ISSN 2300-1895 Source Archive of Mechanical Engineering; 2011; vol. 58; No 4; 425-440 References Antonacci M. (2001), Neurologic complications after lumbar spine surgery, J Am. Academy Ortop. Surg, 9, 2, 137. ; Bibb R. (2011), Computed tomography characterization of additive manufacturing materials, Medical Engineering & Physics, 33, 590, doi.org/10.1016/j.medengphy.2010.12.015 ; Bochenek A. (2007), Anatomia człowieka, I. ; Borkowski P. (2009), Badanie i ocena funkcjonalności nowej konstrukcji endoprotezy wydłużalnej dla pacjentów dorastających, Rozprawa doktorska. ; Chapman J. (2009), Spine Classifications and Severity Measures. ; Chlebus E. (2003), Innowacyjne technologie rapid prototyping - rapid tooling w rozwoju produkt. ; Chua C. (2010), Rapid Prototyping: Principles and Applications, doi.org/10.1142/6665 ; Cierniak R. (2005), Tomografia komputerowa. Budowa urządzeń CT. Algorytmy rekonstrukcyjne. ; A. Dąbrowska Tkaczyk (2011), A surgery simulation of fractured vertebral body relocation on segment of animal spine, Acta of Bioengineering and Biomechanics. ; Dąbrowska-Tkaczyk A. (2008), Evaluation Method for orthotropic properties of the bone tissue in situ, null, 2. ; Dabrowska-Tkaczyk A. (2006), Influence of remodeling stimulating factor selection on bone density distribution in pelvic bone model, Acta of Bioengineering and Biomechanics, 8, 2, 119. ; Dabrowska-Tkaczyk A. (2005), Stress and strain distributions in the bones of hip joint assuming non-homogenous bone material properties, null, 2, 263. ; I. De Castro (2008), Experimental study of ligamentotaxis maneuvers sequencing in vertebral canal decompression, Acta Orthopédica Brasileira, 16, 5, 291, doi.org/10.1590/S1413-78522008000500008 ; Denis F. (1983), The three column spine and its significance in the classification of acute thoracolumbar spine injuries, Spine, 8, 817, doi.org/10.1097/00007632-198311000-00003 ; S Esses (null), Complications associated with the technique of pedicle screw fixation. A selected survey of ABS members 1993, Spine, 2231. ; Gebhardt A. (2007), Generative Fertigungsverfahren. Rapid Prototyping - Rapid Tooling - Rapid Manufactooring. ; Gibson I. (2009), Additive Manufacturing Technologies: Rapid Prototyping to Direct Digital Manufacturing. ; Holdsworth F. (1970), Fractures: Dislocations, and fractures-dislocations of the Spine, J Bone Join Surg, 52-A, 8, 1534, doi.org/10.2106/00004623-197052080-00002 ; Jun-Hong Min (2009), The ligamentotactic effect on a herniated disc at the level adjacent to the anterior lumbar interbody fusion: report of two cases, J Korean Neurosurg Soc, 46, 65, doi.org/10.3340/jkns.2009.46.1.65 ; Lonstein J. (1999), Complications associated with pedicle screws, J Bone Joint Surg (Am), 81A, 11, 1519. ; Magerl F. (1994), Comprehensive Classification of Thoracic and Lumbar Injuries, Eur Spine Journal, J3, 184, doi.org/10.1007/BF02221591 ; McAfee P. (1983), The value of computed tomography in thoracolumbar fractures, J Bone Jonit Surg, 65-A, 4, 461, doi.org/10.2106/00004623-198365040-00006 ; McMinn (2006), Fotograficzny atlas anatomii człowieka. ; Mueller L. A., Mueller L. P., Schmidt R., Forst R., Ruding L.: The phenomenom and efficiency of ligamentotaxis after dorsal stabilization of thoracolumbar burst fractures, 2006. ; Rhin A. (2010), Using magnetic resonance imaging to accurately assess injury to the posterior ligamentous complex of the spine: a prospective comparison of the surgeon and radiologist, J. Neurosurg. Spine, 12, 391, doi.org/10.3171/2009.10.SPINE08742 ; Rohlmann A. (2007), An instrumented implant for vertebral body replacement that measures loads in the anterior spinal column, Med. Eng. Phys, 29, 5, doi.org/10.1016/j.medengphy.2006.06.012 ; Schwartz T. (2002), Radiologia wypadkowa. ; Skalski K. (1999), Zastosowanie wirtualnego i szybkiego prototypowania w procesie projektowania endoprotez dopasowanych, Materiały IV Francusko-Polskiego Seminarium Naukowego Modelowanie i Symulacja Układów Fizycznych i Struktur Technicznych, 21. ; Skalski K. (2000), Ocena alloplastyki stawu biodrowego poprzez szybkie prototypy stereolitograficzne kości i endoprotez, I Krakowskie Warsztaty Inżynierii Medycznej, 147. ; Skoworodko J. (2008), Metodyka projektowania implantu międzykręgowego kręgosłupa lędźwiowego. Rozprawa doktorska. ; A Steffe (1993), The variable screw placement spinal fixation system. Report of a prospective study 250 patients enrolled in Food and Drug Administraction clinical trials, Spine, 18, 1160, doi.org/10.1097/00007632-199307000-00007 ; USS Fracture System Original Instruments and implants of the Association for the Study of Internal Fixation - AO/ASIF. ; Yamauchi T. (2010), Efficacy and reliability of highly functional open source DICOM software (OsiriX) in spine surgery, Journal of Clinical Neuroscience, 17, 756, doi.org/10.1016/j.jocn.2009.09.037 ; Zięba Ł. (2011), Wirtualna stabilizacja kręgosłupa człowieka po złamaniu kompresyjnym na odcinku piersiowo-lędźwiowym, 5, 189. ; CatalystEX R® Pomoc programu. ; <a target="_blank" href='http://www.materialise.com'>www.materialise.com</a> ; <a target="_blank" href='http://www.stratasys.com'>www.stratasys.com</a>