Search results

Filters

  • Journals

Search results

Number of results: 3
items per page: 25 50 75
Sort by:
Download PDF Download RIS Download Bibtex

Abstract

Samples of CdTe single crystals which are used as radiation detectors were periodically measured during a long time interval with different values of an applied voltage. The samples were also periodically exposed during long time periods to high temperatures of 390 K and to rapid changes of temperature from 300 K to 390 K. After 1.5 years of measurements we observed ageing of the samples which resulted in deterioration of their transport characteristics. The resistance of the samples increased significantly and current-voltage characteristics were unstable in time. Noise spectroscopy showed that low frequency noise can be used for detection of CdTe sample ageing as its spectral density increases significantly comparing to the 1/f noise of a high quality sample

Go to article

Authors and Affiliations

Lubomír Grmela
Ondřej Šik
Alexey Andreev
Josef Sikula
Download PDF Download RIS Download Bibtex

Abstract

Studies of electrical properties, including noise properties, of thick-film resistors prepared from various resistive and conductive materials on LTCC substrates have been described. Experiments have been carried out in the temperature range from 300 K up to 650 K using two methods, i.e. measuring (i) spectra of voltage fluctuations observed on the studied samples and (ii) the current noise index by a standard meter, both at constant temperature and during a temperature sweep with a slow rate. The 1/f noise component caused by resistance fluctuations occurred to be dominant in the entire range of temperature. The dependence of the noise intensity on temperature revealed that a temperature change from 300 K to 650 K causes a rise in magnitude of the noise intensity approximately one order of magnitude. Using the experimental data, the parameters describing noise properties of the used materials have been calculated and compared to the properties of other previously studied thick-film materials.

Go to article

Authors and Affiliations

Adam Witold Stadler
Zbigniew Zawiślak
Andrzej Dziedzic
Damian Nowak
Download PDF Download RIS Download Bibtex

Abstract

Noise spectroscopy and I-V characteristic non-linearity measurement were applied as diagnostic tools in order to characterize the volume and contact quality of positive temperature coefficient (PTC) chip sensors and to predict possible contact failure. Correctly made and stable contacts are crucial for proper sensing. I-V characteristics and time dependences of resistance were measured for studied sensors and, besides the samples with stable resistance value, spike type resistance fluctuation was observed for some samples. These spikes often disappear after about 24 hours of voltage application. Linear I-V characteristics were measured for the samples with stable resistance. The resistance fluctuation of burst noise type was observed for some samples showing the I-V characteristic dependent on the electric field orientation. We have found that the thermistors with high quality contacts had a linear I-V characteristic, the noise spectral density is of 1/f type and the third harmonic index is lower than 60 dB. The samples with poor quality contacts show non-linear I-V characteristics and excess noise is given by superposition of g-r and 1/fn type noises, and the third harmonic index is higher than 60 dB.

Go to article

Authors and Affiliations

Lubomír Grmela
Zdenek Sita
Vlasta Sedlakova
Jiri Majzner
Petr Sedlak
Josef Sikula

This page uses 'cookies'. Learn more