In this paper a comparison of numerically determined and measured electromagnetically exited noise of an induction motor is presented. The calculations are accomplished using FEM for an example motor, which is a 290 kW inverter-fed asynchronous machine. The approach starts with the electromagnetic and mechanical consideration. The focus is set on acoustic considerations, which contain the 3D-FE-model and measurement setup in the sound chamber.
This paper presents an analysis of the stator teeth geometry impact on the parameters of the 8-pole radial magnetic bearing. In this paper, such parameters as current gain and position stiffness have been analysed. Additionally, we have proposed criteria for evaluating the characteristics of these parameters by calculating the variability of current gain and position stiffness. The research has been performed by solving the magnetic bearing actuator boundary problem using the finite element method. Magnetic force has been calculated using the Maxwell stress tensor method. Other parameters, such as current gain and position stiffness have been calculated as partial derivate of the force with respect to control current and position of the rotor.
The paper presents the problem of sensorless control of a permanent magnets synchronous motor (PMSM) without a damping cage for fan applications. Frequency control was used according to the principle of v/f = const. In order to reduce the power consumption of the drive system, the optimal voltage to the motor frequency characteristics was tested in the laboratory. The experimental studies was performed on a laboratory set of a drive consisting of two coupled PMSM machines, where one machine was supplied by a transistor inverter and the other was a passive load. A new criterion based on minimizing the module of stator current vector was proposed and an optimization algorithm in steady states was tested. The results of laboratory tests confirmed the validity of the applied solution for the fan drive.
The paper deals with construction of single-phase line start permanent magnet synchronous motor. Circuit-field single-phase line start permanent magnet synchronous motor model based on the mass production single-phase induction motor was applied in Maxwell program. Various rotor constructions were taken into account. Influence of the rotor construction on the motor properties was examined. Running motor performances were examined.
The presented paper concerns a novel concept of hybrid piezoelectric motor based on electroactive lubrication principle. Its structure is combined of quasi-static and resonance piezoelectric actuators, synchronizing their work to generate the rotary movement. The hybrid motor topology is compared to the existing piezoelectric motors, regarding its field of applications in embedded systems with very high security requirements. The electroactive lubrication principle is briefly presented with regards to optimization of the hybrid motor. The performance principle of the hybrid motor is described in terms of its working cycle. The assembling process of the prototype hybrid motor is briefly explained with emphasis put on the frequency and impedance tuning of the applied quasi-static and resonance piezoelectric actuators. Next, the hybrid motor power supply system is described and chosen measured performance characteristics are presented. Finally, conclusions concerning the features of the tested prototype hybrid motor and possible solutions of the faced issues, during assembling and testing, are presented.
In the paper issues related to the design of a robust adaptive fuzzy estimator for a drive system with a flexible joint is presented. The proposed estimator ensures variable Kalman gain (based on the Mahalanobis distance) as well as the estimation of the system parameters (based on the fuzzy system). The obtained value of the time constant of the load machine is used to change the values in the system state matrix and to retune the parameters of the state controller. The proposed control structure (fuzzy Kalman filter and adaptive state controller) is investigated in simulation and experimental tests.
The paper presents the mathematical model of an autonomous induction generator with the AC load circuit and the converter control system of the voltage magnitude at the terminals of stator generator. The control algorithm and the structure of the control system are described. The simulation results of the control system are presented and discussed.
In this paper the design and the magneto-static simulation of axial-flux permanent- magnet stepper motor with the disc type rotor is presented. Disk motors are particularly suitable for electrical vehicles, robots, valve control, pumps, centrifuges, fans, machine tools and manufacturing. The brushless machine with axial flux and permanent magnets, also called the disc-type machine, is an interesting alternative to its cylindrical radial flux counterpart due to the disk shape, compact construction and high torque density. This paper describes a design of four phase microstepping motor with the disc type rotor. The FEM modeling and the 3D magneto-static simulation of the disk stepper motor with permanent magnets is being subject of the article, too. Disc rotor type permanent magnet stepper motor for high torque to inertia ratio is ideal for robotics and CNC machines.
The paper presents the results of research work on the development of a rapidprototyping test stand for testing: servo control algorithms, trajectory generation, algorithms for increasing overall quality of the feed-drive modules within two axis (X-Y) table of the milling machine. Open architecture interface of the prepared control system lets the potential user test functionality of integration of diagnostic tools within the motion controller - directly, without taking into account communication with top-level CNC system.
The paper describes a prototype operator panel, which was designed to operate with the S7-200 family of Programmable Logic Controllers (PLC-s) from Siemens. Most of the functionality of the operator panel was implemented in a computer program, which runs on a PC-class computer. The program communicates with a PLC through its communication port configured in the Freeport mode. Two kinds of interface between the PC, and the PLC are supported: wired, and wireless. For wired connection a standard PC/PPI cable supplied by Siemens is used. For wireless connection two communication modules were designed, which operate in the free 433 MHz band. The operator panel program is intuitive, and easy to use. States of PLC inputs and outputs are presented using graphical objects. It is possible to modify states of the outputs, and monitor and edit any variable in the M and V memory in the PLC. The application supports also alarming. The program can be run on any computer with the MS Windows operating system installed. This makes the solution very cost-effective. Providing both wired and wireless communication radically increases flexibility of the proposed solution. The panel can be quickly mounted in areas, where pulling new cables is inconvenient, difficult or expensive.
A microgrid with parallel structure operating under islanded mode is considered in this paper. Under microgrid islanded operation mode, lines bring adverse effect for power distribution between microsources (MSs). Because traditional droop control ignores this effect, MSs adopting this method can not achieve satisfactory power distribution. A kind of droop control including line compensation applied to this microgrid is proposed. It can eliminate this effect to obtain satisfactory power distribution. The relationship of two kinds of droop control with power distribution is analyzed. The reference voltage generated by droop control is applied to control output voltage of MSs. Comparison of two kinds of droop control through MATLAB/Simulink simulation is made to verify the superiority of droop control including line compensation for power distribution. The relationship between PCC voltage and output power of MSs is also presented.
The paper discusses the application of the current-source concept in the gate drivers for silicon carbide transistors. There is a common expectation that all SiC devices will be switched very fast in order to reach very low values of switching energies. This may be achieved with the use of suitable gate drivers and one of possibilities is a solution with the current source. The basic idea is to store energy in magnetic field of a small inductor and then release it to generate the current peak of the gate current. The paper describes principles of the current-source driver as well as various aspects of practical implementation. Then, the switching performance of the driven SiC transistors is illustrated by double-pulse test results of the normally-ON and normally-OFF JFETs. Other issues such as problem of the drain-gate capacitance and power consumption are also discussed on the base of experimental results. All presented results show that the currentsource concept is an interesting option to fast and efficient driving of SiC transistors.
The positive asymptotically stable continuous-time linear systems are approximated by corresponding asymptotically stable discrete-time linear systems. Two methods of the approximation are presented and the comparison of the methods is addressed. The considerations are illustrated by three numerical examples and an example of positive electrical circuit.
ARCHIVES OF ELECTRICAL ENGINEERING (AEE) (previously Archiwum Elektrotechniki), quarterly journal of the Polish Academy of Sciences is OpenAccess, publishing original scientific articles and short communiques from all branches of Electrical Power Engineering exclusively in English. The main fields of interest are related to the theory & engineering of the components of an electrical power system: switching devices, arresters, reactors, conductors, etc. together with basic questions of their insulation, ampacity, switching capability etc.; electrical machines and transformers; modelling & calculation of circuits; electrical & magnetic fields problems; electromagnetic compatibility; control problems; power electronics; electrical power engineering; nondestructive testing & nondestructive evaluation.
Manuscript submission:
All manuscripts should be submitted electronically on Editorial System.
Submission of paper to the Archives of Electrical Engineering is understood to imply that the article is original, unpublished and is not being considered for publication elsewhere. All articles will be reviewed. Since 2013, Authors wishing to use the facility of colour printing should consult the editors.
Template:
Microsoft Word is recommended as a standard word processor to prepare the paper to the AEE journal. If you use the LaTex format, please transfer your document to Microsoft Word and then use Template AEE.
While editing your paper, make sure that all the mathematical characters (symbols, identifiers, variables, vectors, axis marks, etc.) have the required shape, thickness, and slant kept throughout the whole article. The same appearance of a given mathematic character must be retained regardless of its place (text, equations, tables or figures).
The articles that don’t conform to the above will not be processed and published.
The reviewing process:
Each paper submitted for publication in Archives of Electrical Engineering is subjected to the following review procedure:
a) the paper is reviewed by the editor in chief or guest editor for general suitability for publication in AEE
b) if it is judged suitable two reviewers are selected and a double blind peer review process takes place
c) based on the recommendations of the reviewers, the editor then decides whether the paper should be accepted in its present form, revised or rejected
d) the author(s) is(are) informed by e-mail on the results of the reviewing procedure.
The papers are published on average within 3 months after acceptance.
Requirements for preparation of manuscripts:
The manuscript submitted for publication should have no less than 12 pages and no more than 16 pages. In the case of the manuscript longer than 16 pages, please contact the AEE Editorial Board before submitting your paper. The manuscripts, written in UK English, should be typed using Template AEE according to the following instructions and should include: a title page with the title of a manuscript, a short title; abstract; key words, text; list of references. A DOI number as well as received and revised data will be completed by Editor. When you open Template.doc, select "Print Layout" from the "View" menu in the menu bar (View > Print Layout). Then type over sections of Template.doc or cut and paste from another document and then use markup styles (Home > Styles). For example, the style at this point in the document is "main text").
All papers submitted for publication are assessed on the basis of the mutual anonymity rule as to the names of reviewers and authors. Authors' names and affiliations should not appear in the attached text/tables/figures.
If English is not your first language, ask an English-speaking colleague to proofread your manuscript. The manuscripts that fail to meet basic standards of literacy are likely to be immediately declined or after the language assessment, sent to the authors for linguistic improvement.
The manuscripts are published on average within 3 months after their acceptance.
Do not change the font sizes or line spacing to squeeze more text into a limited number of pages. Leave some open space around your figures.
The AEE journal publishes an ORCID for all authors. You will need a registered ORCID in order to submit your paper for peer review. ORCID registration is free and only takes a minute. Please note that ORCIDs will be added in the course of the author's proofreads.
Text:
The pages must be numbered consecutively. Articles should be divided into numbered sections, and if necessary subsections, preferably: Introduction, Material, Methods, Results, Conclusion and References. Any special characters (e.g. Greek, script, etc.) should be named in the margin where the character first occurs in the text. Names of species are to be accentuated with wavy underlining (italics). Equations should be numbered serially (1), (2), ... on the right side of the page. Footnotes should be avoided, if required, they should be used only for brief notes which do not fit well into the text. Figures and tables have to be included into the text. If table is typed on a separate page its position in the text should be marked. Abbreviations should be explained when they first appear in the text.
Math:
Please use the MathML editor as well as MathType editor to build an equation in your manuscript.
Equations:
Equations should be typed within the text, centred, and should be numbered consecutively throughout the text. Their numbers should be typed in parentheses, flush right. Equations should be referred to in text, e.g. (1), except at the beginning of a sentence: "Equation (1) is ...". All symbols appearing in equations have to be defined in the text, before or just after the equation.
If the symbols are written in Times New Roman use italic fonts. Symbols of vectors and matrices should be written in bold fonts. Do not italicize Greek fonts and mathematical symbols like e.g.: the derivative symbol d, max, min, etc. The indices of symbols that are indices themselves should be written in a clear manner.
Note that the equation is centered using a center tab stop. Please keep the same font in the formulas and text.
Unit Symbols, Abbreviations:
Define abbreviations and acronyms the first time they are used in the text, even after they have been defined in the abstract. Abbreviations such as IEEE, SI, MKS, CGS, sc, dc, and rms do not have to be defined. Do not use abbreviations in the title or heads unless they are unavoidable.
Si units are recommended for use in formulas, drawings and tables., for example the SI unit for magnetic field strength H is A/m. Apply the center dot to separate compound units.
Do not mix complete spellings and abbreviations of units: "Wb/m2" or "webers per square meter," not "webers/m2." Spell units when they appear in text: "...a few henries…", not "...a few H…".
Use a zero before decimal points: "0.25," not ".25." Use "cm3," not "cc."
Unit Symbols, SI Prefixes as well as Abbreviations should be writing in accordance with the IEEE standard
Tables, figures (illustrations) and captions:
The illustrations (line diagrams and photographs) should be suitable for direct reproduction. The lettering as well the details should have proportional dimensions to maintain their legibility after the usual reduction. All illustrations should be numbered consecutively (Fig. X). Tables are numbered with Arabic numerals.
All figures, figure captions, and tables in the text must be inserted into the correct places.
Figures, photos, tables or other parts of a manuscript that have previously appeared in another publication or are not the property of the authors must be properly acknowledged in the manuscript. Permission to republish these items must be obtained by the corresponding author from a person or institution holding the copyright, usually the publisher.
Authors are requested to send all drawings used in the article in additional files. Create a separate file for each image. Images should be submitted in a bitmap format (.jpeg) or/and in a vector format (.eps, .pdf or .cdr). Each file must be saved according to the number in the original article, e.g.: FIG1.JPG, FIG2.EPS, or FIG3.PDF. Bitmap illustrations must be “flattened”, which means no additional layers, for example, covering old descriptions.
Photographs, colour, and greyscale figures should be at least at a resolution of 400 dpi.
All colour figures should be generated in the RGB or CMYK colour space, while greyscale images in the greyscale colour space.
When preparing your figures/graphics etc., we suggest the use of the Arial 8 point font for axis numbers and Arial 9 point font for axis names. Figures/graphics etc. can be prepared in one of two proposed ways - see Template AEE.
Tables are numbered with Arabic numerals. Use 9 point Times New Roman for the title of the table and 9 point Times New Roman for the filling of the table (9 in the case of symbols with subscripts).
AEE journal allows an author to publish color figures in e-version at no charge, and automatically convert them to grayscale for print versions. Authors wishing to use the facility of color printing should consult the editors.
Conclusions:
A conclusion might elaborate on the importance of the work or suggest applications and extensions. Although a conclusion may review the main points of the manuscript, do not replicate the abstract as the conclusion.
References:
References in text must be numbered consecutively by Arabic numerals placed in square brackets. Please make sure that you use full names of journals i.e. Archives of Electrical Engineering. Please ensure that all references in the Reference list are cited in the text and vice versa.
Please provide name(s) and initials of author(s), the title of the manuscript, editors (if any), the title of the journal or book, a volume number, the page range, and finally the year of publication in brackets.
You can use the rules presented on the site: IEEE standard.
Examples of the ways in which references should be cited are given below:
Journal manuscript
[1] Author1 A., Author2 A., Title of paper, Title of periodical, vol. x, no. x, pp. xxx-xxx (YEAR).
example
[1] Steentjes S., von Pfingsten G., Hombitzer M., Hameyer K., Iron-loss model with consideration of minor loops applied to FE-simulations of electrical machines, IEEE Transactions on Magnetics. vol. 49, no. 7, pp. 3945-3948 (2013).
[2] Idziak P., Computer Investigation of Diagnostic Signals in Dynamic Torque of Damaged Induction Motor, Electrical Review (in Polish), to be published.
[3] Cardwell W., Finite element analysis of transient electromagnetic-thermal phenomena in a squirrel cage motor, submitted for publication in IEEE Transactions on Magnetics.
Conference manuscript
[4] Author A., Title of conference paper, Unabbreviated Name of Conf., City of Conf., Country of Conf., pp. xxx-xxx (YEAR).
example
[4] Popescu M., Staton D.A., Thermal aspects in power traction motors with permanent magnets, Proceedings of XXIII Symposium Electromagnetic Phenomena in Nonlinear Circuits, Pilsen, Czech Republic, pp. 35-36 (2016).
Book, book chapter and manual
[5] Author1 A., Author2 A.B., Title of book, Name of the publisher (YEAR).
example
[5] Zienkiewicz O., Taylor R.L., Finite Element method, McGraw-Hill Book Company (2000).
Patent
[6] Author1 A., Author2 A., Title of patent, European Patent, EP xxx xxx (YEAR).
example
[6] Piech Z., Szelag W., Elevator brake with magneto-rheological fluid, European Patent, EP 2 197 774 B1 (2011).
Thesis
[7] Author A., Title of thesis, PhD Thesis, Department, University, City of Univ. (YEAR).
example
[7] Driesen J., Coupled electromagnetic-thermal problems in electrical energy transducers, PhD Thesis, Faculty of Applied Science, K.U. Leuven, Leuven (2000).
For on electronic forms
[8] Author A., Title of article, in Title of Conference, record as it appears on the copyright page], © [applicable copyright holder of the Conference Record] (copyright year), doi: [DOI number].
example
[8] Kubo M., Yamamoto Y., Kondo T., Rajashekara K., Zhu B., Zero-sequence current suppression for open-end winding induction motor drive with resonant controller,in IEEE Applied Power Electronics Conference and Exposition (APEC), © APEC (2016), doi: 10.1109/APEC.2016.7468259
Website
[9] http://www.aee.put.poznan.pl, accessed April 2010.
Proofs:
Authors will receive proofs for correction, which should be returned promptly. All joint contributions must indicate the name and address of the authors to whom proofs should be sent.
Fees for printing the papers in Archives of Electrical Engineering:
AEE is published in Open Access, which means that all articles are available on the internet to all users immediately upon publication free of charge for the readers. Authors will be asked to a declaration that they are ready to cover the costs of printing their article.
The fee for the publication of an article in the AEE journal is 200 Euro.
Abstracting & Indexing:
Archives of Electrical Engineering is covered by the following services:
Preparation of manuscript for Archives of Electrical Engineering (AEE)