Applied sciences

Metrology and Measurement Systems

Content

Metrology and Measurement Systems | 2013 | No 1

Download PDF Download RIS Download Bibtex

Abstract

There is an ongoing debate about the fundamental security of existing quantum key exchange schemes. This debate indicates not only that there is a problem with security but also that the meanings of perfect, imperfect, conditional and unconditional (information theoretic) security in physically secure key exchange schemes are often misunderstood. It has been shown recently that the use of two pairs of resistors with enhanced Johnsonnoise and a Kirchhoff-loop ‒ i.e., a Kirchhoff-Law-Johnson-Noise (KLJN) protocol ‒ for secure key distribution leads to information theoretic security levels superior to those of today’s quantum key distribution. This issue is becoming particularly timely because of the recent full cracks of practical quantum communicators, as shown in numerous peer-reviewed publications. The KLJN system is briefly surveyed here with discussions about the essential questions such as (i) perfect and imperfect security characteristics of the key distribution, and (ii) how these two types of securities can be unconditional (or information theoretical).

Go to article

Authors and Affiliations

Robert Mingesz
Laszlo Bela Kish
Zoltan Gingl
Claes-Göran Granqvist
He Wen
Ferdinand Peper
Travis Eubanks
Gabor Schmera
Download PDF Download RIS Download Bibtex

Abstract

This elaboration presents the method of virtual positioning of the construction of an endoprosthesis of hip joint in a patient’s pelvis and femoral bone, reconstructed on the basis of imaging obtained from computer tomography. It is based on the matching of an implant to individual anatomical-biomechanical conditions. The method is established on the following procedures: diagnostic, spatial modeling, virtual measuring and targeted biometrological application for the model of bone structures. The final effect of the completed procedures is selection and optimal positioning of the endoprosthesis of hip joint before a planned medical intervention. The determined geometrical parameters of bone structures and settled positioning of the endoprosthesis can create data for the system of computer navigation.

Go to article

Authors and Affiliations

Anna Maria Ryniewicz
Andrzej Ryniewicz
Tomasz Madej
Jerzy Sładek
Adam Gąska
Download PDF Download RIS Download Bibtex

Abstract

In this paper we introduce a self-tuning Kalman filter for fast time-domain amplitude estimation of noisy harmonic signals with non-stationary amplitude and harmonic distortion, which is the problem of a contactvoltage measurement to which we apply the proposed method. The research method is based on the self-tuning of the Kalman filter's dropping-off behavior. The optimal performance (in terms of accuracy and fast response) is achieved by detecting the jump of the amplitude based on statistical tests of the innovation vector of the Kalman filter and reacting to this jump by adjusting the values of the covariance matrix of the state vector. The method's optimal configuration of the parameters was chosen using a statistical power analysis. Experimental results show that the proposed method outperforms competing methods in terms of speed and accuracy of the jump detection and amplitude estimation.

Go to article

Authors and Affiliations

Uroš Kovač
Andrej Košir
Download PDF Download RIS Download Bibtex

Abstract

The paper presents the family of three analyzers allowing to measure impedance in the range of 10 Ω<|Zx|<10 GΩ in a wide frequency range from 10 mHz up to 100 kHz. The most important features of the analyzer family are: miniaturization, low power consumption, low production cost, telemetric controlling and the use of an impedance measurement method based on digital signal processing (DSP). The miniaturization and other above-mentioned features of the analyzers were obtained thanks to the use of the newest generation of large-scale integration chips: e.g. “system on a chip” microsystems (AD5933), 32-bit AVR32-family microcontrollers and specialized modules for wireless communication using the ZigBee standard. When comparing metrological parameters, the developed instrumentation can equal portable analyzers offered by top worldwide manufacturers (Gamry, Ivium) but outperforms them on smaller dimensions, weight, a few times lower price and the possibility to work in a distributed telemetric network. All analyzer versions are able to be put into medium-volume production.

Go to article

Authors and Affiliations

Jerzy Hoja
Grzegorz Lentka
Download PDF Download RIS Download Bibtex

Abstract

In this paper, we present a synthesis of the parameters of the fiber Bragg grating (FBG) and the reconstruction of the distributed strain affecting the grating, performed by means of its reflection spectrum. For this purpose, we applied the transition matrix method and the Nelder-Mead nonlinear optimization method. Reconstruction results of the strain profile carried out on the basis of a simulated reflection spectrum as well as measured reflection spectrum of the FBG indicate good agreement with the original strain profile; the profile reconstruction errors are within the single digit percentage range. We can conclude that the Nelder-Mead optimization method combined with the transition matrix method can be used for distributed sensing problems.

Go to article

Authors and Affiliations

Małgorzata Detka
Download PDF Download RIS Download Bibtex

Abstract

This paper presents a novel strategy of particle filtering for state estimation based on Generalized Gaussian distributions (GGDs). The proposed strategy is implemented with the Gaussian particle pilter (GPF), which has been proved to be a powerful approach for state estimation of nonlinear systems with high accuracy and low computational cost. In our investigations, the distribution which gives the complete statistical characterization of the given data is obtained by exponent parameter estimation for GGDs, which has been solved by many methods. Based on GGDs, an extension of GPF is proposed and the simulation results show that the extension of GPF has higher estimation accuracy and nearly equal computational cost compared with the GPF which is based on Gaussian distribution assumption.

Go to article

Authors and Affiliations

Xifeng Li
Yongle Xie
Download PDF Download RIS Download Bibtex

Abstract

Improvements of modern manufacturing techniques implies more efficient production but also new challenges for coordinate metrologists. The crucial task here is a coordinate measurement accuracy assessment. It is important because according to technological requirements, measurements are useful only when they are stated with their accuracy. Currently used methods for the measurements accuracy estimation are difficult to implement and time consuming. It is therefore important to implement correct and validated methods that will also be easy to implement. The method presented in this paper is one of them. It is an on-line accuracy estimation method based on the virtual CMM idea. A model is built using a modern LaserTracer system and a common test sphere and its implementation lasts less than one day. Results obtained using the presented method are comparable to results of commonly used uncertainty estimation methods which proves its correct functioning. Its properties predispose it to be widely used both in laboratory and industrial conditions.

Go to article

Authors and Affiliations

Jerzy Sładek
Adam Gąska
Magdalena Olszewska
Robert Kupiec
Marcin Krawczyk
Download PDF Download RIS Download Bibtex

Abstract

The paper presents a new elastic scheduling task model which has been used in the uniprocessor node of a control measuring system. This model allows the selection of a new set of periods for the occurrence of tasks executed in the node of a system in the case when it is necessary to perform additional aperiodic tasks or there is a need to change the time parameters of existing tasks. Selection of periods is performed by heuristic algorithms. This paper presents the results of the experimental use of an elastic scheduling model with a GRASP heuristic algorithm.

Go to article

Authors and Affiliations

Wiesław Miczulski
Piotr Powroźnik
Download PDF Download RIS Download Bibtex

Abstract

In this paper, a modified form of the Gabor Wigner Transform (GWT) has been proposed. It is based on adaptive thresholding in the Gabor Transform (GT) and Wigner Distribution (WD). The modified GWT combines the advantages of both GT and WD and proves itself as a powerful tool for analyzing multi-component signals. Performance analyses of the proposed distribution are tested on the examples, show high resolution and crossterms suppression. To exploit the strengths of GWT, the signal synthesis technique is used to extract amplitude varying auto-components of a multi-component signal. The proposed technique improves the readability of GWT and proves advantages of combined effects of these signal processing techniques.

Go to article

Authors and Affiliations

Muhammad Ajab
Imtiaz Ahmad Taj
Imran Shafi
Srdjan Stankovic
Download PDF Download RIS Download Bibtex

Abstract

Various components of surface texture are identified, namely form, waviness and roughness. Separation of these components is done by digital filtering. Several problems exist during analysis of two-process surfaces. Therefore the Gaussian robust profile filtering technique was established and has been studied here. The computer generated 2D profiles and 3D surface topographies having triangular scratches as well as measured stratified surfaces were subjected to filtration. However even robust filter applications cause distortion of profiles having valleys wider than 100 μm. In order to minimize the distortion associated with wide and deep valleys, the robust filter should be modified. A special procedure was elaborated for minimizing distortion of roughness profiles caused by filtration. Application of this method to analyses of several profiles was presented. The difference between 1-D and 2-D filtering of surface topography using the same kind of filter was discussed. As a result we found that modification of a 2-D surface topography filter was not necessary.

Go to article

Authors and Affiliations

Paweł Pawlus
Paweł Dobrzański
Download PDF Download RIS Download Bibtex

Abstract

One of the most important parameters in the study of diffraction gratings is their optical efficiency. This paper analyzes the different manufacturing processes to cover gratings of Moiré interferometry and their influence on the quality and absolute efficiency of replicated gratings on the surfaces of specimens. The Moiré interferometry is a field measurement technique that has been used in many different fields such as applied mechanics, microelectronics, biomechanics or micromechanics, hence the importance of this study. The applied reflected coating was done by sputtering and aluminium vaporization processes. In this work different materials and thickness layers were analyzed. The obtained coatings have a high degree of reflectivity on the replicated gratings.

Go to article

Authors and Affiliations

João Eduardo Ribeiro
Download PDF Download RIS Download Bibtex

Abstract

Digital photoelasticity is an important optical metrology follow-up for stress and strain analysis using full-field digital photographic images. Advances in digital image processing, data acquisition, procedures for pattern recognition and storage capacity enable the use of the computer-aided technique in automation and facilitate improvement of the digital photoelastic technique. The objective of this research is to find new equations for a novel phase-shifting method in digital photoelasticity. Some innovations are proposed. In terms of phaseshifting, only the analyzer is rotated, and the other equations are deduced by applying a new numerical technique instead of the usual algebraic techniques. This approach can be used to calculate a larger sequence of images. Each image represents a pattern and a measurement of the stresses present in the object. A decrease in the mean errors was obtained by increasing the number of observations. A reduction in the difference between the theoretical and experimental values of stresses was obtained by increasing the number of images in the equations for calculating phase. Every photographic image has errors and random noise, but the uncertainties due to these effects can be reduced with a larger number of observations. The proposed method with many images and high accuracy is a good alternative to the photoelastic techniques.

Go to article

Authors and Affiliations

Cristina Almeida Magalhães
Perrin Smith Neto
Pedro Américo Almeida Magalhães Júnior
Clovis Sperb de Barcellos
Download PDF Download RIS Download Bibtex

Abstract

Wavelet transform becomes a more and more common method of processing 3D signals. It is widely used to analyze data in various branches of science and technology (medicine, seismology, engineering, etc.). In the field of mechanical engineering wavelet transform is usually used to investigate surface micro- and nanotopography. Wavelet transform is commonly regarded as a very good tool to analyze non-stationary signals. However, to analyze periodical signals, most researchers prefer to use well-known methods such as Fourier analysis. In this paper authors make an attempt to prove that wavelet transform can be a useful method to analyze 3D signals that are approximately periodical. As an example of such signal, measurement data of cylindrical workpieces are investigated. The calculations were performed in the MATLAB environment using the Wavelet Toolbox.

Go to article

Authors and Affiliations

Krzysztof Stępień
Włodzimierz Makieła

Instructions for authors



Sample article with Author guidelines



Author guidelines



Types of contributions

Metrology and Measurement Systems welcomes submissions of the following article types:

• invited special issue or review papers presenting the current stage of the knowledge within scope of the journal (about 20 edited pages, approximately 3000 characters each),
• research papers reporting high-quality original scientific or technological advancements (max. 12 pages),
• papers based on extended and updated contributions presented at scientific conferences (max. 12 pages),
• short notes, i.e. book reviews, conference reports, short news (max. 2 pages).


Manuscript preparation

General The text of a manuscript should be written in clear and concise English. The camera-ready format – with attached separate files containing illustrations, tables and photographs – is required. A cover letter with clear explanation of scientific novelty of the paper is strongly recommended. Papers based on extended and updated contributions presented at scientific conferences, or strongly related to previous authors’ works, must be accompanied with a cover letter file, which should explain in details changes made in the manuscript in comparison with the original conference paper and highlight the novelty in reference to other authors’ works.
The main text of a manuscript should be printed on an A4 page (with margins of 2.5 cm) using Times New Roman style with a font size of 12 pt; the paragraphs should start with the indentation of 5 mm, and titles should be written in bold. That text can be divided into sections (numbered 1, 2, …), first-order subsections (numbered 1.1., 1.2., …, written in italics), and – if needed – second-order subsections (numbered 1.1.1., 1.1.2., …, written same as first-order subsections). The only acceptable manuscript formats are in Microsoft Word (.doc, .docx).

The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors. The Editor encourages the Authors of submitted papers who are not English native speakers, to use a language service checking the language correctness not only with respect to grammar, but also in the way of presentation of research results accepted by renowned publishers, e.g. presented on the website of the European Association of Science Editors.


Figures
Figures (illustrations, photographs) and tables, provided in the camera-ready form suitable for reproduction (which may include reduction), should be additionally submitted (one per page), larger than the final size. While preparing figures we encourage to start with defining expected size and minimum font size that fit to all graphics in the manuscript – using the same style in all of your graphics visually improves the article. Final figure formats must be in one of the following: (vectors) .eps, .pdf, .ai or .cdr, and (bitmaps) .bmp, .gif, .tif or .jpg.
As far as plots, block diagrams, schematics etc. are concerned, we suggest to use one of vector formats to improve quality and scalability. Figures in vector formats must be saved using RGB colours and with fully white background (0% K). Hidden layers are unacceptable. Minimum line thickness printed in a single colour is 0.25 pt (0.09 mm), and 1 pt (0.36 mm) when using more colours. Typically we suggest 0.2-0.5 mm but in particular cases the range 0.1–1.0 mm will be accepted. Lines in plots should be distinguished not only by using different colours but also using different line types and markers, if needed.


Equation
All equations must be numbered consecutively throughout the text. Each equation should be preceded and followed by a 6-point spacing. Punctuate equations when they are part of a sentence. Equation numbers should be enclosed in parentheses. Equations should be prepared with the use of MathType or Microsoft Equation editors. The type size in the equation is the same as for the text. To make your equations more compact, you may use the appropriate mathematical symbols or expressions. The symbols used in an equation have to be defined before that equation or immediately after it. Use italics for variables (e.g. i, x, n), physical quantity symbol (e.g. voltage U, temperature T), letter pointers and general function symbols. Do not use italics for constants, indexes, minimum, maximum and trigonometric functions, mathematical operators, differentials, etc. To refer to the equation use “(1)”, not “Eq. (1)” or “equation (1)”, except at the beginning of a sentence where “Equation (1)” should be used. We recommend to use International System of Units SI i.e. metre-kilogram-second system of units. As a decimal separator dot should be used in the entire manuscript (text, figures, tables).


References
The paper has to be clearly positioned in the context of relevant literature in the field of measurements and instrumentation. Note that lack of references from the main field of Metrology and Measurement Systems interest may suggest that the content of manuscript does not exactly correspond to the scope of metrological journals. It may reduce possibility that a proposed paper will be read by audience society. In such a case our Editorial Board may suggest to send the manuscript to a more appropriate journal. Also note that the use of possibly up-to-date references may indicate importance of your work. Table below gives examples of some relevant and renewable journals related to widely understood metrology.


Journal

Publisher

ISSN

Metrologia

IOP Publishing

0026-1394

IEEE Transactions on Instrumentation and Measurement

IEEE

0018-9456

Measurement

Elsevier

0263-2241

Measurement Science and Technology

IOP Publishing

0957-0233

Metrology and Measurement Systems

PAS

0860-8229

Review of Scientific Instruments

IOP Publishing

0034-6748

IEEE Transactions on Industrial Electronics

IEEE

1557-9948

IET Science, Measurement & Technology

IET

1751-8822

Journal of Instrumentation

SISSA, IOP Publishing

1748-0221

Measurement Science Review

Walter de Gruyter

1335-8871

IEEE Instrumentation and Measurement Magazine

IEEE

1094-6969

Bulletin of the Polish Academy of Sciences: Technical Sciences

PAS

2300-1917

Opto-Electronics Review

PAS

1896-3757

IEEE Sensors Journal

IEEE

1558-1748

Sensors

MDPI

1424-8220




References should be inserted in the text in square brackets, i.e. [1]; their list, numbered in citation order, should appear at the end of the manuscript. The format of the references should follow the APA 7th edition formatting style, i.e.: for an journal paper – surname(s) and initial(s) of author(s), year in brackets, title of the paper, full journal name, volume, issue (in brackets) and page numbers. Put all author names unless there are more than 20. Otherwise, after the first 19 authors’ names, use an ellipsis in place of the remaining author names. Then, end with the final author’s name (do not place an ampersand before it).


Submission process
Manuscript should be submitted via the Internet Editorial System (IES) – an online submission and peer review system. In order to submit the manuscript via the IES, the authors (first-time users) must create an author account to obtain a user ID and password required to enter the system. The submission of the manuscript in a single file, i.e. “Article File” containing the complete manuscript (with all figures of high quality and tables embedded in the text), is preferred. All figures have to be uploaded in separate files. The generated PDF file has to be approved. The PDF file has lower quality of the embedded figures to limit its size only.
The submission of a manuscript means that its content has not been published previously, it is not under consideration for publication elsewhere, and that – if accepted – it will not be published elsewhere. The Author hereby grants the Polish Academy of Sciences (the Journal Owner) the license for commercial use of the article according to the Open Access License ( CC BY-NC-ND 4.0), which has to be signed before publication. The copyright form is available in the IES.
The Authors are urged to suggest 4 to 5 reviewers in their application (with names, affiliations and addresses) with whom the Editorial Board could co-operate while processing the paper. Proposed reviewers should be experts deeply involved in issues related to the subject matter of the paper and they are intended to come from different universities or research centres.
Each submitted manuscript is subject to a single-blind peer-review procedure, and the publication decision is based on the reviewers’ comments. If necessary, the authors may be invited to revise their manuscripts. On acceptance, manuscripts are subject to editorial amendment to exactly fit the journal style.
An essential criterion for the evaluation of submitted manuscripts is their potential impact on the research field, measured by the number of repeated quotations. Such papers are preferred at the evaluation and publication stages.
Proofs will be sent to the corresponding author by e-mail and should be returned within 48 hours from receipt. The publication in the journal is free of charge. A sample copy of the journal will be sent to the corresponding author free of charge. For colour pages the authors will be charged at the rate of 160 PLN or 80 EUR per page. The payment to the bank account of the main distributor (given in “Subscription Information”) must be completed before the date indicated by the Editorial Office.


Other information
It is possible to include supplementary files related to the article content, such as e.g. developed databases. These files can be then used by other researchers to compare their algorithms using the same input data. For more details about supplementary files please contact the Editorial Board: metrology@wat.edu.pl. The biographical statements, at the very end of the article, are not obligatory, however, they are kindly recommended. Each statement should include the author’s full name and brief personal history focused on areas of research and scientific achievements. The biographical statement may not exceed 100 words and should be written using Times New Roman style with a font size of 8 pt.
The publication of your article is a great achievement but then it needs to be further promoted to make it more visible to the research community. Responsibility for this task lies with the Authors and our Editorial Board. We guarantee free access to the article in the Journals PAN of the Polish Academy of Science, including articles in Early Access form (published just after acceptance decision), indexing in popular and renewable databases (e.g. Thomson Scientific Master Journal List, Elsevier’s Scopus, Google Scholar). Furthermore, selected articles are highlighted on the journal website and are reprinted for promotion at conferences and other events. The Authors can share the final form of the article on various social networks and research-sharing platforms, such as Twitter, Facebook, Linkedin, ResearchGate, Academia.edu, SciProfiles. They are also encouraged to update personal and institutional webpages by adding the title and a link of the article. Feel free also to share your work with your colleagues using any other methods that do not conflict with the CC BY-NC-ND 4.0 license.
For more detailed description about how to write a paper for the Metrology and Measurement Systems journal please look at the Author guidelines for manuscript preparation. We strongly recommend using this file as a template for manuscript preparation.


This page uses 'cookies'. Learn more