Nauki Techniczne

Opto-Electronics Review

Zawartość

Opto-Electronics Review | 2015 | vol. 23 | No 1

Abstrakt

Infrared (IR) science and technology has been mainly dedicated to surveillance and security: since the 70’s specialized techniques have been emerging in thermal imaging for medical and cultural heritage diagnostics, building and aeronautics structures control, energy savings and remote sensing. Most of these applications were developed thanks to IR FPAs sensors with high numbers of pixels and, actually, working at room temperatures. Besides these technological achievements in sensors/ receivers, advanced developments of IR laser sources up to far IR bands have been achieved in the form QCL (quantum cascade laser), allowing wide band TLC and high sensitivity systems for security. recently new sensors and sources with improved performances are emerging in the very far IR region up to submillimeter wavelengths, the so called terahertz (THz) region.

A survey of the historical growth and a forecast of the future developments in Devices and Systems for the new frontier of IR will be discussed, in particular for the key questions: “From where and when is IR coming?”, “Where is it now?” and “Where will it go and when?”. These questions will be treated for key systems (Military/Civil), key devices (Sensors/ Sources), and new strategic technologies (Nanotech/TeraHertz).

Przejdź do artykułu

Autorzy i Afiliacje

C. Corsi

Abstrakt

This study is based on the investigation of AlSb layer thickness effect on heavy−hole light−hole (HH−LH) splitting and band gap energies in a recently developed N−structure based on InAs/AlSb/GaSb type II superlattice (T2SL) p−i−n photodetector.eFirst principle calculations were carried out tailoring the band gap and HH−LH splitting energies for two possible interface transition alloys of InSb and AlAs between InAs and AlSb interfaces in the superlattice. Results show that AlSb and InAs−GaSb layer thicknesses enable to control HH−LH splitting energies to desired values for Auger recombination process where AlSb/GaSb total layer thickness is equal to InAs layers for the structures with InSb and AlAs interfaces

Przejdź do artykułu

Autorzy i Afiliacje

M.M. Alyoruk
Y. Ergun
M. Hostut

Abstrakt

We describe an all−in−fibre apparatus for Constant Intensity Direct Absorption Spectroscopy (CIDAS) for gas concentration measurements which keeps the power of a diode laser constant along the frequency sweep. The reduction of the large variation of the laser power, connected to the frequency scan, enhances the ability of detecting small variations in a background signal, resulting in an increase of the sensitivity with respect to standard direct absorption techniques. Moreover, CIDAS allows for a real−time observation of the absorption signals without any kind of post−detection processing. The apparatus has been tested with carbon dioxide (CO2) and methane (CH4), around 1.57 and 1.65 μm, respectively.

Przejdź do artykułu

Autorzy i Afiliacje

A. Montori
M. Pas de
M. Giuntini
M. Siciliani Cumis de
S. Viciani
F. D’Amato

Abstrakt

In this paper the experimental results of piezoelectric and magnetostrictive ultrasonic stimulation are comparatively analyzed in the evaluation of impact damage in a graphite epoxy composite sample chosen for a round robin test. By comparing theoretical and experimental results, it is shown that the equivalent power of internal friction can reach some hundreds mill watt per a single crack.

Przejdź do artykułu

Autorzy i Afiliacje

W. Swiderski
V. Vavilov

Abstrakt

Metal nanoshells are a type of nanoparticle composed by a dielectric core and a metallic coating. These nanoparticles have stimulated interest due to their remarkable optical properties. In common with metal colloids, they show distinctive absorption peaks at specific wavelengths due to surface plasmon resonance. However, unlike bare metal colloids, the wavelengths at which resonance occurs can be tuned by changing the core radius and coating thickness. One basic application of such property is in medicine, where it is hoped that nanoshells with absorption peaks in the near−infrared can be attached to cancerous cells. In this paper, we study the changes of optical response in visible and near infrared wavelengths from single to randomly distributed clusters of nanoshells. The results were obtained using a novel formulation of Mie theory in evanescent wave conditions, with a finite−difference time−domain (FDTD) simulation and experimentally on BaTiO3−gold nanoshells using a scanning near−optical microscope. The results show that the optical signal of a randomly distributed cluster of nanoshells can be supplementary tuned with respect to the case of single nanoshell depending by the geometric configuration of the clusters.

Przejdź do artykułu

Autorzy i Afiliacje

A. Cricenti
M. Luce
D. Moroni
O. Salvetti
M. D’Acunto

Abstrakt

We describe a new method to separate ballistic from the scattered photons for optical tissue characterization. It is based on the hypothesis that the scattered photons acquire a phase delay. The photons passing through the sample without scattering or absorption preserve their coherence so they may participate in interference. We implement a Mach−Zehnder experimental setup where the ballistic photons pass through the sample with the delay caused uniquely by the sample indices of refraction. We incorporate a movable mirror on the piezoelectric actuator in the sample arm to detect the amplitude of the modulation term. We present the theory that predicts the path−integrated (or total) concentration of the scattering and absorption centres. The proposed technique may characterize samples with transmission attenuation of ballistic photons by a factor of 10-14.

Przejdź do artykułu

Autorzy i Afiliacje

F. Corral
M. Strojnik
G. Paez

Abstrakt

Skin dynamic termography supplemented by a mathematical model is presented as an objective and sensitive indicator of the skin prick test result. Termographic measurements were performed simultaneously with routine skin prick tests. The IR images were acquired every 70 s up to 910 s after skin prick. In the model histamine is treated as the principal mediator of the allergic reaction. Histamine produces vasolidation and the engorged vessels are responsible for an increase in skin temperature. The model parameters were determined by fitting the analytical solutions to the spatio-temporal distributions of the differences between measured and baseline temperatures. The model reproduces experimental data very well (coefficient of determination = 0.805÷0.995). The method offers a set of parameters to describe separately skin allergic reaction and skin reactivity. The release of histamine after allergen injection is the best indicator of allergic response. The diagnostic parameter better correlates with the standard evaluation of a skin prick test (correlation coefficient = 0.98) than the result of the thermographic planimetric method based on temperature and heated area determination (0.81). The high sensitivity of the method allows for determination of the allergic response in patients with the reduced skin reactivity.

Przejdź do artykułu

Autorzy i Afiliacje

E. Rokita
T. Rok
G. Tatoń

Abstrakt

Trophic disorders like reduced skin blood circulation are well−known epiphenomenon of cerebral palsy (CP). They can influence quality of life and can lead to skin damages and, as a consequence, to decubitus. Therefore, it is important to analyse temperature regulation in patients with CP. Thermal imaging camera FLIR BCAM SD was used to study the dependency of skin blood circulation in upper extremities of patients with CP on hand dominance, hand force and hand volume. The hand force was evaluated using a conventional dynamometer. The hand volume was measured with a volumeter. A cold stress test for hands was applied in 22 patients with CP and 6 healthy subjects. The warming up process after the test was recorded with the thermal camera. It was confirmed that the hands of patients warm up slower comparing to healthy persons. The patients’ working hands warm up faster than non−working ones. A slight correlation was established between the hand grip force of the working hands and their warm up time. No correlation was found between the warming up time and the volume of the hand. The results confirm our assumption that there is a connection of peripheral blood circulation to upper limb motor functions.

Przejdź do artykułu

Autorzy i Afiliacje

R. Lampe
S. Kawelke
J. Mitternacht
V. Turova
T. Blumenstein
A. Alves-Pinto

Abstrakt

Automated motion reduction in dynamic infrared imaging is on demand in clinical applications, since movement disarranges time−temperature series of each pixel, thus originating thermal artifacts that might bias the clinical decision. All previously proposed registration methods are feature based algorithms requiring manual intervention. The aim of this work is to optimize the registration strategy specifically for Breast Dynamic Infrared Imaging and to make it user−independent. We implemented and evaluated 3 different 3D time−series registration methods: 1. Linear affine, 2. Non−linear Bspline, 3. Demons applied to 12 datasets of healthy breast thermal images. The results are evaluated through normalized mutual information with average values of 0.70 ±0.03, 0.74 ±0.03 and 0.81 ±0.09 (out of 1) for Affine, Bspline and Demons registration, respectively, as well as breast boundary overlap and Jacobian determinant of the deformation field. The statistical analysis of the results showed that symmetric diffeomorphic Demons’ registration method outperforms also with the best breast alignment and non−negative Jacobian values which guarantee image similarity and anatomical consistency of the transformation, due to homologous forces enforcing the pixel geometric disparities to be shortened on all the frames. We propose Demons’ registration as an effective technique for time−series dynamic infrared registration, to stabilize the local temperature oscillation.

Przejdź do artykułu

Autorzy i Afiliacje

S. Riyahi-Alam
V. Agostini
F. Molinari
M. Knaflitz

Abstrakt

Aerial thermography is performed from a low−cost aerial vehicle, copter type, for the acquisition of data of medium−size areas, such as neighbourhoods, districts or small villages. Thermographic images are registered in a mosaic subsequently used for the generation of a thermographic digital terrain model (DTM). The thermographic DTM can be used with several purposes, from classification of land uses according to their thermal response to the evaluation of the building prints as a function of their energy performance, land and water management. In the particular case of buildings, apart from their individual evaluation and roof inspection, the availability of thermographic information on a DTM allows for the spatial contextualization of the buildings themselves and the general study of the surrounding area for the detection of global effects such as heat islands.

Przejdź do artykułu

Autorzy i Afiliacje

S. Lagüela
L. Díaz-Vilariño
D. Roca
H. Lorenzo

Abstrakt

Energy efficiency and reduction of building consumption are deeply felt issues both at Italian and international level. The recent regulatory framework sets stringent limits on energy performance of buildings. Awaiting the adoption of these principles, several methods have been developed to solve the problem of energy consumption of buildings, among which the simplified energy audit is intended to identify any anomalies in the building system, to provide helpful tips for energy refurbishments and to raise end users’ awareness. The Energy Signature is an operational tool of these methodologies, an evaluation method in which energy consumption is correlated with climatic variables, representing the actual energy behaviour of the building. In addition to that purpose, the Energy Signature can be used as an empirical tool to determine the real performances of the technical elements. The latter aspect is illustrated in this article.

Przejdź do artykułu

Autorzy i Afiliacje

L. Belussi
L. Danza
I. Meroni
F. Salamone

Abstrakt

Infrared (IR) reflectography has been used for many years for the detection of underdrawings on panel paintings. Advances in the fields of IR sensors and optics have impelled the wide spread use of IR reflectography by several recognized Art Museums and specialized laboratories around the World. The transparency or opacity of a painting is the result of a complex combination of the optical properties of the painting pigments and the underdrawing material, as well as the type of illumination source and the sensor characteristics. For this reason, recent researches have been directed towards the study of multispectral approaches that could provide simultaneous and complementary information of an artwork. The present work relies on non−simultaneous multispectral inspection using a set of detectors covering from the ultraviolet to the terahertz spectra. It is observed that underdrawings contrast increases with wavelength up to 1700 nm and, then, gradually decreases. In addition, it is shown that IR thermography, i.e., temperature maps or thermograms, could be used simultaneously as an alternative technique for the detection of underdrawings besides the detection of subsurface defects.

Przejdź do artykułu

Autorzy i Afiliacje

A. Bendada
S. Sfarra
C. Ibarra-Castanedo
M. Akhloufi
J.P. Caumes
C. Pradere
J.C. Batsale

Abstrakt

The subflorescence and efflorescence phenomena are widely acknowledged as the major causes of permanent damage to fresco wall paintings. They are related to the occurrence of cycles of dry/wet conditions inside the walls. Therefore, it is essential to identify the presence of water on the decorated surfaces and inside the walls.

Nondestructive testing in industrial applications have confirmed that active infrared thermography with continuous timed images acquisition can improve the outcomes of thermal analysis aimed to moisture identification. In spite of that, in cultural heritage investigations these techniques have not been yet used extensively on a regular basis. This paper illustrates an application of these principles in order to evaluate the decay of fresco mural paintings in a medieval chapel located in North−West of Italy. One important feature of this study is the use of a robotic system called aIRview that can be utilized to automatically acquire and process thermal images. Multiple accurate thermal views of the inside walls of the building have been produced in a survey that lasted several days. Signal processing algorithms based on Fast Fourier Transform analysis have been applied to the acquired data in order to formulate trustworthy hypotheses about the deterioration mechanisms.

Przejdź do artykułu

Autorzy i Afiliacje

G. Cadelano
P. Bison
A. Bortolin
G. Ferrarini
F. Peron
M. Girotto
M. Volinia

Abstrakt

This paper presents and assesses an inverse heat conduction problem (IHCP) solution procedure which was developed to determine the local convective heat transfer coefficient along the circumferential coordinate at the inner wall of a coiled pipe by applying the filtering technique approach to infrared temperature maps acquired on the outer tube’s wall. The data−processing procedure filters out the unwanted noise from the raw temperature data to enable the direct calculation of its Laplacian which is embedded in the formulation of the inverse heat conduction problem. The presented technique is experimentally verified using data that were acquired in the laminar flow regime that is frequently found in coiled−tube heat−exchanger applications. The estimated convective heat transfer coefficient distributions are substantially consistent with the available numerical results in the scientific literature.

Przejdź do artykułu

Autorzy i Afiliacje

F. Bozzoli
L. Cattani
G. Pagliarini
S. Rainieri

Abstrakt

Non−uniformity noise, it was, it is, and it will probably be one of the most non−desired attached companion of the infrared focal plane array (IRFPA) data. We present a higher order filter where the key advantage is based in its capacity to estimates the detection parameters and thus to compensate it for fixed pattern noise, as an enhancement of Constant Statistics (CS) theory. This paper shows a technique to improve the convergence in accelerated way for CS (AACS: Acceleration Algorithm for Constant Statistics). The effectiveness of this method is demonstrated by using simulated infrared video sequences and several real infrared video sequences obtained using two infrared cameras

Przejdź do artykułu

Autorzy i Afiliacje

A.G. Jara-Chavez
F.O. Torres-Vicencio

Instrukcja dla autorów

Guide for Authors

https://www.editorialsystem.com/opelre/journal/for_authors/

OPTO-ELECTRONICS REVIEW is an open access journal. This involves the payment of an article publishing charge (APC) by the authors, their institution or funding body. We make the article freely available immediately upon publication on PAS Jornals platform (https://journals.pan.pl/opelre)

Article publishing charge: the flat fee of 400 EUR (in PLN 1 750) per paper (see the above link with instructions for Authors for details)

Dodatkowe informacje

Opto-Electronics Review was established in 1992 for the publication of scientific papers concerning optoelectronics and photonics materials, system and signal processing. This journal covers the whole field of theory, experimental verification, techniques and instrumentation and brings together, within one journal, contributions from a wide range of disciplines. Papers covering novel topics extending the frontiers in optoelectronics and photonics are very encouraged. The main goal of this magazine is promotion of papers presented by European scientific teams, especially those submitted by important team from Central and Eastern Europe. However, contributions from other parts of the world are by no means excluded.

Articles are published in OPELRE in the following categories:

-invited reviews presenting the current state of the knowledge,

-specialized topics at the forefront of optoelectronics and photonics and their applications,

-refereed research contributions reporting on original scientific or technological achievements,

-conference papers printed in normal issues as invited or contributed papers.

Authors of review papers are encouraged to write articles of relevance to a wide readership including both those established in this field of research and non-specialists working in related areas. Papers considered as “letters” are not published in OPELRE.

Opto-Electronics Review is published quarterly as a journal of the Association of Polish Electrical Engineers (SEP) and Polish Academy of Sciences (PAS) in cooperation with the Military University of Technology and under the auspices of the Polish Optoelectronics Committee of SEP.

Abstracting and Indexing:

Arianta

BazTech

EBSCO relevant databases

EBSCO Discovery Service

SCOPUS relevant databases

ProQuest relevant databases

Clarivate Analytics relevant databases

WangFang

additionally:

ProQuesta (Ex Libris, Ulrich, Summon)

Google Scholar

Policies and ethics:

The editors of the journal place particular emphasis on compliance with the following principles:

Ethical policy of Opto-Electronics Review

The ethical policy of Opto-Electronics Review follows the European Code of Conduct for Research Integrity and is also guided by the core practices and policies outlined by the Committee on Publication Ethics (COPE).

Authors must be honest in presenting their results and conclusions of their research. Research misconduct is harmful for knowledge.

Research results

Fabrication, falsification, or selective reporting of data with the intent to mislead or deceive is unethical, as is the theft of data or research results from others. The results of research should be recorded and maintained to allow for analysis and review. Following publication, the data should be retained for a reasonable period and made available upon request. Exceptions may be appropriate in certain circumstances to preserve privacy, to assure patent protection, or for similar reasons.

Authorship

All those who have made a significant contribution should be given chance to be cited as authors. Other individuals who have contributed to the work should be acknowledged. Articles should include a full list of the current institutional affiliations of all authors, both academic and corporate.

Competing interests

All authors, referees and editors must declare any conflicting or competing interests relating to a given article. Competing interests through their potential influence on behavior or content or perception may undermine the objectivity, integrity, or perceived value of publication.

Peer Review

We are committed to prompt evaluation and publication of fully accepted papers in Opto-Electronics Review’s publications. To maintain a high-quality publication, all submissions undergo a rigorous review process.

Characteristics of the peer review process are as follows:

• Simultaneous submissions of the same manuscript to different journals will not be tolerated.

• Manuscripts with contents outside the scope will not be considered for review.

• Opto-Electronics Review is a single-blind review journal.

• Papers will be refereed by at least 2 experts as suggested by the editorial board.

• In addition, Editors will have the option of seeking additional reviews when needed. Authors will be informed when Editors decide further review is required.

• All publication decisions are made by the journal’s Editor-in-Chief based on the referees’ reports. Authors of papers that are not accepted are notified promptly.

• All submitted manuscripts are treated as confidential documents. We expect reviewers to treat manuscripts as confidential material.

• Editors and reviewers involved in the review process should disclose conflicts of interest resulting from direct competitive, collaborative, or other relationships with any of the authors, and remove oneself from cases in which such conflicts preclude an objective evaluation. Privileged information or ideas that are obtained through peer review must not be used for competitive gain.

• A reviewer should be alert to potential ethical issues in the paper and should bring these to the attention of the editor, including any substantial similarity or overlap between the manuscript under consideration and any other published paper of which the reviewer has personal knowledge. Any statement, observation, derivation, or argument that had been previously reported should be accompanied by the relevant citation.

• Personal criticism is inappropriate.

Plagiarism

Reproducing text from other papers without properly crediting the source (plagiarism) or producing many papers with almost the same content by the same authors (self-plagiarism) is not acceptable. Submitting the same results to more than one journal concurrently is unethical. Exceptions are the review articles. Authors may not present results obtained by others as if they were their own. Authors should acknowledge the work of others used in their research and cite publications that have influenced the direction and course of their study.

Plagiarism is not tolerated. All manuscripts submitted to Opto-Electronics Review will be checked for plagiarism (copying text or results from other sources) and self-plagiarism (duplicating substantial parts of authors’ own published work without giving the appropriate references) using the CrossCheck database (iThenticate plagiarism checker).

Duplicate submission

Simultaneous submissions of the same manuscript to different journals will not be tolerated. The submitted article will be removed without consideration.

Corrections and retractions

All authors have an obligation to inform and cooperate with journal editors to provide prompt retractions or correction of errors in published works.

• The journal will issue retractions if:

• There is clear evidence that the findings are unreliable, either as a result of misconduct (e.g., data fabrication or honest error - miscalculation or experimental error);

• The findings have previously been published elsewhere without proper cross-referencing, permission or justification (i.e., cases of redundant publication);

• It constitutes plagiarism;

• It reports unethical research.

• The journal will issue errata, if:

• A small portion of an otherwise reliable publication proves to be misleading (especially because of honest error);

• The author list is incorrect.

Other forms of misconduct include failure to meet clear ethical and legal requirements such as misrepresentation of interests, breach of confidentiality, lack of informed consent and abuse of research subjects or materials. Misconduct also includes improper dealing with infringements, such as attempts to cover up misconduct and reprisals on whistleblowers.

The primary responsibility for handling research misconduct is in the hands of those who employ the researchers. If a possible misconduct is brought to our attention, we will seek advice from the referees and the Editorial Board. If there is the evidence, we will resolve the matter by appropriate corrections in the printed and online journal; by refusing to consider an author's future work and by contacting affected authors and editors of other journals.

Human and Animal Rights

If the work involves the use of human subjects, the author should ensure that the work described has been carried out in accordance with The Code of Ethics of the World Medical Association (Declaration of Helsinki) for experiments involving humans; Uniform Requirements for manuscripts submitted to Biomedical journals. Authors should include a statement in the manuscript that informed consent was obtained for experimentation with human subjects. The privacy rights of human subjects must always be observed.

All animal experiments should comply with the ARRIVE guidelines and should be carried out in accordance with the EU Directive 2010/63/EU for animal experiments, and the authors should clearly indicate in the manuscript that such guidelines have been followed.

Ta strona wykorzystuje pliki 'cookies'. Więcej informacji